Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Angiography by means of micro-computed tomography (m-CT) is extensively used for the diagnosis of vasculature disorders. To establish a connection between m-CT images and genuine histopathology findings, we developed two novel titanium dioxide nanoparticle (TiO-NP)-based perfusion contrast agents: TiNpCA-1 and TiNpCA-2. Three-dimensionally reconstructed m-CT images in mice perfused with these contrast agents showed high resolution and accuracy in various organs without deformation or dilation of vessels. Vessels < 20 m in diameter were clearly visualized by m-CT, and capillaries of 4 m in diameter were visualized by nano-CT. After perfusion, the contrast agents were kept in the vessels by the formation of an aggregate with ethanol. Histological samples were prepared from CT-scanned specimens. No perfusion-induced damage or abnormal structures were observed. The signals of the contrast agents were detected clearly, and the tissue histology was of adequate quality for pathological diagnosis. Agglomerates of TiO-NPs were present in both agents; their approximate sizes were 1.0 and 6.0 m in TiNpCA-1 and 1.5 m in TiNpCA-2. We considered that these agglomerates were trapped within capillaries at the beginning of perfusion. And at the end of perfusion, vessels of larger size were filled with agglomerates. These findings suggest a direct correlation between the signal intensity in m-CT imaging and the volume of contrast agent entering the vessels, indicating a quantitative aspect to the system. The low -edge value of titanium (4.6 KeV) ensures that the signal intensity of the contrast agent remains unaffected at low energies (40 KeV). Lower energy levels improve the contrast-to-noise ratio. Consequently, using titanium dioxide as a contrast agent allows us to achieve a higher contrast-to-noise ratio while maintaining a favorable signal-to-noise ratio. Our results strongly support the notion that TiO-NPs as a contrast agents hold promise not only for investigating circulatory disorders in experimental pathology but also for uncovering new insights in anatomical physiology.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11824794 | PMC |
http://dx.doi.org/10.1155/ijbi/6688558 | DOI Listing |