A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Feasibility and safety of biologic OviTex mesh in ventral mesh rectopexy: a prospective pilot study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Minimal-invasive ventral mesh rectopexy (VMR) is a widely accepted treatment for patients suffering from rectal prolapse. The type of mesh used in VMR remains a subject of debate. Currently, the most applied implant is a polypropylene mesh. The aim of the present pilot study was to determine the ease of use, feasibility, and safety of OviTex PGA mesh, a biologic mesh, in VMR.

Methods: Consecutive patients who underwent VMR for internal or external rectal prolapse were included in a prospective non-randomised pilot study in two centers. Preoperative and postoperative evaluation (90 days and 6 months) with a clinical examination and questionnaire regarding pelvic floor symptoms was performed. The primary objectives were to monitor the perioperative technical end result and the postoperative complication rate.

Results: Sixteen patients underwent VMR with an OviTex PGA implant. All operations were completed successfully and without intraoperative complications. The mean ODS and FISI score was significantly decreased after 6-months follow-up. No graft-related complications (GRC) occurred. Two patients developed a recurrent prolapse within 6 months.

Conclusion: Robotic correction of rectal prolapse using an OviTex mesh is a safe, minimally invasive, technically feasible treatment. However, further research is warranted to evaluate the potential added value of OviTex compared to polypropylene mesh on a larger scale. Long-term follow-up is essential to assess the durability of the procedure and monitor the occurrence of any new symptoms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11825524PMC
http://dx.doi.org/10.1007/s10151-024-03097-wDOI Listing

Publication Analysis

Top Keywords

pilot study
12
rectal prolapse
12
mesh
9
feasibility safety
8
ovitex mesh
8
ventral mesh
8
mesh rectopexy
8
polypropylene mesh
8
ovitex pga
8
patients underwent
8

Similar Publications