A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessing multiple MRI sequences in deep learning-based synthetic CT generation for MR-only radiation therapy of head and neck cancers. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study investigated the effect of multiple magnetic resonance (MR) sequences on the quality of deep-learning-based synthetic computed tomography (sCT) generation in the head and neck region.

Materials And Methods: 12 MR series (T1pre-, T1post-contrast, T2 each with 4 Dixon images) were collected from 26 patients with head and neck cancers. 14 unique deep-learning models using the U-Net framework were trained using multiple MRs as inputs to generate sCTs. Mean absolute error (MAE), Dice Similarity Coefficient (DSC), as well as Gamma pass rates were used to compare sCTs to the actual CT across the different multi-channel MR-sCT models.

Results: Using all available MR series yielded sCTs with the lowest pixel-wise error (MAE = 80.5 ± 9.9 HU), but increasing channels also increased artificial tissue which led to poorer auto-contouring and lower dosimetric accuracy. Models with T2 protocols generally resulted in poorer quality sCTs. Pre-contrast T1 with all Dixon images was the best multi-channel MR-sCT model, consistently ranking high for all sCT quality measurements (average DSC across all structures = 80.0 % ± 13.6 %, global Gamma Pass Rate = 97.9 % ± 1.7 % at 2 %/2mm dose criterion and 20 % of max dose threshold).

Conclusions: Deep-learning networks using all Dixon images from a pre-contrast T1 sequence as multi-channel inputs produced the most clinically viable sCTs. Our proposed method may enable MR-only radiotherapy planning in a clinical setting for head and neck cancers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2025.110782DOI Listing

Publication Analysis

Top Keywords

head neck
16
neck cancers
12
dixon images
12
error mae
8
gamma pass
8
multi-channel mr-sct
8
scts
5
assessing multiple
4
multiple mri
4
mri sequences
4

Similar Publications