Quantifying radiotherapy beam quality: an analysis using gamma passing rates.

Biomed Phys Eng Express

Department of Radiation Oncology, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, Fujian, 361001, People's Republic of China.

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

. PDD and profile curves play a crucial role in analyzing the beam quality and energy stability of accelerators. The aim of this study was to assess the efficacy of GPR in machine QA and compare it with traditional methods for analyzing dose outputs.. GPRs were employed to assess the quality of radiation beams by comparing 1D and 2D Profile metrics and PDD data against commissioning data. The data used were obtained from the ASCII data files derived from the water tank. GPRs were calculated for all plots with a lower percentage dose cutoff of 10%. The local GPRs and dose influence for the 2D PDD metrics and dose influence were calculated for an open field 10 × 10 cmphoton beam at SSD = 100 cm. In both 1D and 2D GPRs analyses, criterion of 1%/1 mm was adopted, as this approach allows for the capture of more subtle variations in the data. To substantiate the viability of the study, a comparative analysis was conducted by comparing the outcomes of the gamma analysis with those derived from traditional methods, such as manual machine quality assurance checks.. GPRs demonstrated a superior capability for comprehensive data analysis compared to traditional methods. For the 1D curves, the passing rates (≤ 1) are 96.19%, 100%, and 93.46%, respectively. With respect to the 2D dose influence, the PDD image passing rate was 99.57%, and significant dose differences were observed at the four corners of the open field, indicating areas that require further investigation.. Compared to traditional methods, GPRs are more sensitive to subtle changes in the data, providing valuable insights into the accelerator beam status.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2057-1976/adb291DOI Listing

Publication Analysis

Top Keywords

traditional methods
16
dose influence
12
beam quality
8
passing rates
8
influence pdd
8
open field
8
compared traditional
8
data
7
dose
6
gprs
6

Similar Publications

Background: The high and increasing rate of poor mental health among young people is a matter of global concern. Experiencing poor mental health during this formative stage of life can adversely impact interpersonal relationships, academic and professional performance, and future health and well-being if not addressed early. However, only a few of those in need seek help.

View Article and Find Full Text PDF

Auricular reconstruction is essential for restoring facial symmetry and achieving a well-contoured, natural-appearing ear. Traditional methods using autologous costal cartilage often delay reconstruction until around age 10, when sufficient rib cartilage is available, which can pose physical and psychological challenges for pediatric patients. Porous high-density polyethylene (PHDPE) implants offer significant advantages, including the ability to perform reconstruction earlier, reduced morbidity, improved ear definition, and the possibility of a single-stage outpatient procedure.

View Article and Find Full Text PDF

Finite Element Analysis of Mandibular Distraction Osteogenesis With a New Partially Bioabsorbable Distractor.

J Craniofac Surg

September 2025

Department of Craniomaxillofacial Surgery, Peking Union Medical College, Chinese Academy of Medical Sciences, Plastic Surgery Hospital, Beijing, China.

Objective: We designed a new distractor pairing a bioabsorbable upper fixing plate fixed by bioabsorbable screws with a traditional titanium distractor to simplify the second surgery removing the distractor after mandibular distraction osteogenesis. The present study aims to evaluate its biomechanical properties using finite element method.

Materials And Methods: Ten computer-aided designed models simulating mandibles of 5 patients under 2 working conditions, the instance of distraction and mastication, were produced.

View Article and Find Full Text PDF

Fibrin Sealant-Assisted Fixation of an Autologous Iliac Bone Graft in Orbital Floor Reconstruction.

J Craniofac Surg

September 2025

Division of Ophthalmic Plastic and Reconstructive Surgery, Sadik Eratik Eye Institute, Haydarpasa Numune Education and Research Hospital, University of Health Sciences.

Orbital floor fractures can lead to enophthalmos and diplopia, often requiring surgical intervention to restore orbital volume. Autologous iliac bone grafts are commonly used due to their biocompatibility and mechanical stability, but achieving adequate fixation remains a challenge. Traditional fixation methods, such as plates and screws, may introduce risks of foreign body reactions, graft displacement, and surgical morbidity.

View Article and Find Full Text PDF

Background: Breast cancer is the most common cancer among women and a leading cause of mortality in Europe. Early detection through screening reduces mortality, yet participation in mammography-based programs remains suboptimal due to discomfort, radiation exposure, and accessibility issues. Thermography, particularly when driven by artificial intelligence (AI), is being explored as a noninvasive, radiation-free alternative.

View Article and Find Full Text PDF