Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Research Question: The goal of this study was to assess the diagnostic accuracy of spinal time-resolved contrast-enhanced MR angiography (4D-MRA) for the detection and localization of spinal dural arteriovenous fistulas (SDAVF) in our institution.

Material And Methods: Single center retrospective cohort study of patients with the clinical suspicion of a SDAVF. Patients were included who had undergone spinal 4D-MRA in the period January 2010-February 2021. A subgroup was identified, who had subsequent digital subtraction angiography (DSA), or clinical/radiological follow-up. Diagnostic performance measures of 4D-MRA were calculated (sensitivity, positive predictive value, specificity, and negative predictive value) with DSA serving as the reference standard.

Results: Overall, 120 patients with the clinical suspicion of having a SDAVF and who underwent spinal 4D-MRA were identified. A subgroup of 30 patients had both 4D-MRA and DSA, or follow-up. In this group, the sensitivity of 4D-MRA for the detection of a SDAVF was 100% and specificity was 91% (positive predictive value of 95% and a negative predictive value of 100%). Sidedness was correctly identified on 4D-MRA in 74% of the cases and the level of the SDAVF in 68%.

Discussion And Conclusion: The results indicate that 4D-MRA has a high sensitivity and specificity for the detection and localization of a SDAVF, which is in line with previous studies published in literature. Furthermore, 4D-MRA can serve to guide DSA and shorten the procedural time, which reduces the risk of angiography related complications, and decreases patient discomfort.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753963PMC
http://dx.doi.org/10.1016/j.bas.2024.104176DOI Listing

Publication Analysis

Top Keywords

4d-mra detection
12
detection localization
12
4d-mra
10
diagnostic accuracy
8
localization spinal
8
spinal dural
8
dural arteriovenous
8
arteriovenous fistulas
8
cohort study
8
patients clinical
8

Similar Publications

Research Question: The goal of this study was to assess the diagnostic accuracy of spinal time-resolved contrast-enhanced MR angiography (4D-MRA) for the detection and localization of spinal dural arteriovenous fistulas (SDAVF) in our institution.

Material And Methods: Single center retrospective cohort study of patients with the clinical suspicion of a SDAVF. Patients were included who had undergone spinal 4D-MRA in the period January 2010-February 2021.

View Article and Find Full Text PDF
Article Synopsis
  • * A systematic review and meta-analysis revealed that 4D-MRA has a very high sensitivity of 98.2% and a specificity of 88.2% compared to DSA for detecting SDAVFs.
  • * The findings suggest that 4D-MRA can accurately locate SDAVFs and potentially streamline the diagnostic process, reducing patient discomfort and procedural risks associated with DSA.
View Article and Find Full Text PDF
Article Synopsis
  • This study evaluates the effectiveness of non-contrast-enhanced 4D MR angiography (NCE-4D-MRA) versus contrast-enhanced 4D MR angiography (CE-4D-MRA) for diagnosing brain arteriovenous malformations (bAVMs), using digital subtraction angiography (DSA) as a reference.
  • Researchers analyzed MRA results from 43 patients and found that NCE-4D-MRA had higher accuracy (0.85) and specificity (95%) than CE-4D-MRA (0.83 accuracy and 85% specificity).
  • The study suggests that NCE-4D-MRA might be a safer diagnostic option for bAVMs, providing
View Article and Find Full Text PDF
Article Synopsis
  • Brain AVMs are congenital vascular abnormalities in the brain that can lead to serious issues like hemorrhage or seizures, and while various treatments exist, accurate imaging is key for effective management, particularly after radiosurgery.
  • Current imaging techniques, like Digital Subtraction Angiography (DSA), are effective but invasive, prompting a systematic review to assess the efficacy of MRI sequences for post-radiosurgery monitoring of AVMs.
  • The analysis of 14 studies revealed that MRI demonstrates high sensitivity (85%) and specificity (99%), with different sequences like 4D MRA and ASL providing varying diagnostic accuracies, making MRI a promising tool for monitoring AVMs without the invasive risks associated with DSA.
View Article and Find Full Text PDF

Current and Future Applications of Arterial Spin Labeling MRI in Cerebral Arteriovenous Malformations.

Biomedicines

March 2024

Division of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Piazza Spedali Civili 1, 25123 Brescia, Italy.

Article Synopsis
  • Arterial spin labeling (ASL) is a noninvasive imaging technique that shows promise for assessing arteriovenous malformations (AVMs) in both children and adults, with its own set of advantages and challenges.
  • While ASL effectively identifies feeder arteries and assesses blood flow, its performance may not always match that of traditional methods like digital subtraction angiography (DSA), particularly in visualizing venous drainage.
  • There are uncertainties regarding its sensitivity for certain AVM features, especially in complex locations, highlighting the need for larger studies to better understand ASL's diagnostic capabilities.
View Article and Find Full Text PDF