A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate the predictive accuracy of 11 intraocular lens (IOL) calculation formulas in eyes with an axial length (AL) less than 22.00 mm.

Methods: New-generation formulas (Barrett Universal II [BUII], Emmetropia Verifying Optical [EVO] 2.0, Hill-Radial Basis Function [Hill-RBF] 3.0, Hoffer QST, K6, Kane, Pearl-DGS) and traditional formulas (Haigis, Hoffer Q, Holladay 1 and SRK/T) were evaluated for predictive accuracy. Subgroup analyses were performed based on AL and anterior chamber depth (ACD).

Results: The study enrolled a total of 184 eyes from 184 patients. The BUII, Hoffer QST, Hoffer Q, Holladay 1, and SRK/T showed myopic shifts (-0.49 to -0.18 diopters [D], P < 0.05), whereas K6 displayed a hyperopic shift (0.11 D, P = 0.03). The Kane exhibited no systematic bias (-0.07 D), and yielded lower mean absolute error (MAE) (0.48 D, P < 0.05) and root mean square absolute error (RMSAE) (0.65 D, P < 0.01). For eyes with an AL ≤ 21.5 mm and an ACD > 2.5 mm, the Pearl-DGS displayed the smallest MAE (0.43 D) and lowest RMSAE (0.57 D), while other new-generation formulas showed relatively worse performance (MAE: 0.46 to 0.67 D; RMSAE: 0.60 to 0.84 D).

Conclusion: The Kane formula showed the highest accuracy in short eyes, whereas the Pearl-DGS had superior performance in eyes with a relatively shorter AL and deeper ACD.

Clinical Trial Number: Not applicable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11737209PMC
http://dx.doi.org/10.1186/s12886-024-03793-zDOI Listing

Publication Analysis

Top Keywords

intraocular lens
8
axial length
8
anterior chamber
8
chamber depth
8
predictive accuracy
8
hoffer qst
8
hoffer holladay
8
holladay srk/t
8
lens calculation
4
calculation formula
4

Similar Publications