A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

A promising high-sensitive 1D photonic crystal magnetic field sensor based on the coupling of Fano\Tamm resonance in far IR region. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This paper presents a novel investigation of a magnetic sensor that employs Fano/Tamm resonance within the photonic band gap of a one-dimensional crystal structure. The design incorporates a thin layer of gold (Au) alongside a periodic arrangement of Tantalum pentoxide ([Formula: see text]) and Cesium iodide ([Formula: see text]) in the configuration [Formula: see text]. We utilized the transfer matrix method in conjunction with the Drude model to analyze the formation of Fano/Tamm states and the permittivity of the metallic layer, respectively. These states can be manipulated based on the left-handed and right-handed circular polarization of electromagnetic waves, along with an applied magnetic field. Several key parameters were optimized, including material selection, layer thickness, unit cell periodicity, and the angle of incidence, to enhance the sensor performance. Additionally, we investigated how variations in magnetic field strength influence the position of Fano/Tamm resonance in the reflectivity spectrum of the interacting electromagnetic waves within a specific wavelength range of 60 μm to 140 μm. The proposed sensor displays good performance investigated by calculating several parameters like, sensitivity, figure of merit, quality factor and resolution. One of them, it shows a maximum sensitivity of 57 nm/Tesla within a magnetic field strength of 20 to 140 Tesla, positioning it as a promising candidate for various applications in magnetic field measurement and telecommunications, particularly in the unique far-infrared region.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11732997PMC
http://dx.doi.org/10.1038/s41598-025-85747-zDOI Listing

Publication Analysis

Top Keywords

magnetic field
20
[formula text]
12
fano/tamm resonance
8
electromagnetic waves
8
field strength
8
magnetic
6
field
5
promising high-sensitive
4
high-sensitive photonic
4
photonic crystal
4

Similar Publications