A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Focal volume reduction in transcranial focused ultrasound using spherical wave expansions. | LitMetric

Focal volume reduction in transcranial focused ultrasound using spherical wave expansions.

Ultrasonics

School of Biological Science and Medical Engineering, Beihang University, Beijing, China. Electronic address:

Published: April 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Transcranial focused ultrasound (tFUS) has been gaining increased attention as a non-invasive modality for treating brain diseases. However, accurately focusing on brain structures remains a challenge as the ultrasound is severely distorted by the presence of the skull. In this article, we propose a promising distortion correction method based on spherical wave expansions. It is demonstrated that the focal gain is directly related to the zero-order spherical harmonic coefficient, and suppressing higher-order coefficients significantly reduces the focal volume. Simulation results show that this method can correct distortion and effectively balance focal gain and volume, achieving a smaller focal spot with lower grating lobes compared to the commonly used time reversal technique. We also verified the capability of shifting the focal position in real time without additional simulations. This work provides an effective approach for tFUS treatments, offering enhanced precision and reduced focal volume.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2025.107564DOI Listing

Publication Analysis

Top Keywords

focal volume
12
transcranial focused
8
focused ultrasound
8
spherical wave
8
wave expansions
8
focal gain
8
focal
7
volume reduction
4
reduction transcranial
4
ultrasound spherical
4

Similar Publications