Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Peri-implantitis is characterized as a pathological change in the tissues around dental implants. Fourier-transform infrared spectroscopy (FTIR) provides molecular information from optical phenomena observed by the vibration of molecules, which is used in biological studies to characterize changes and serves as a form of diagnosis.
Aims: this case-control study evaluated the peri-implant disease by using FTIR spectroscopy with attenuated total reflectance in the fingerprint region.
Methods: 38 saliva samples were evaluated, 17 from the control group and 21 from the peri-implantitis group. Clinical data such as plaque index (PI), gingival index, probing depth (PS), and attachment level were assessed.
Results: The results of clinical parameters showed a statistical difference between the two groups regarding an excess of the PI. In the FTIR-ATR analysis, the main components revealed vibrational modes of fatty acids, histidine, lipid esters, nucleic acids, and tryptophan, with the main molecules contributing to spectral discrimination. The five-component partial least-squares discriminant analysis classification model had an accuracy of 81%, showing differences between healthy and diseased implants.
Conclusion: the FTIR spectroscopy provides important molecular characteristics of the samples and the results in association with clinical data show the effectiveness of using this tool for diagnosing the disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11812000 | PMC |