A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The effect of carbon fiber custom dynamic orthosis type on kinematics and kinetics of lower extremity joints in individuals with lower limb traumatic injuries. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Carbon fiber custom dynamic orthoses have been used to improve gait mechanics after lower limb trauma in military service members, with the goal of restoring function and improving outcomes. However, the effects of commercially available carbon fiber orthoses available to civilians on lower extremity joint kinetics and kinematics are poorly understood.

Research Question: The aim of this study was to examine the effect of two commercially available orthoses on lower extremity kinematics and kinetics in individuals with lower limb trauma.

Methods: A total of 23 participants with a lower extremity traumatic injury underwent gait analysis while walking without an orthosis, and while wearing a monolithic carbon fiber orthosis or while wearing a modular carbon fiber orthosis, in a randomized order. Study participants accommodated to each orthosis for three months prior to testing. Joint kinematics and kinetics at the ankle, knee, and hip joints, and ground reaction forces were assessed.

Results: The two study orthoses significantly reduced ankle motion compared to no orthosis, with large effect sizes observed. Peak plantarflexor moment was greater with the modular orthosis compared to the monolithic orthosis. Ankle push-off power did not differ between orthoses but was significantly reduced relative to no orthosis. Push-off power with the study orthoses was over 25% greater as compared to previous studies with military orthoses. Peak loading response power generation at the knee was greater with the monolithic orthosis as compared to the modular orthosis. The kinematics and kinetics at the hip did not differ between orthoses.

Significance: Orthoses commonly used in civilian settings to treat limb trauma primarily alter joint kinematics and kinetics at the ankle, in a manner consistent with orthoses used in the military. Additionally, despite the apparent large differences in the designs of the two study orthoses, between-orthosis differences on gait mechanics were limited.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12292513PMC
http://dx.doi.org/10.1016/j.gaitpost.2024.12.024DOI Listing

Publication Analysis

Top Keywords

carbon fiber
20
kinematics kinetics
20
lower extremity
16
lower limb
12
study orthoses
12
orthosis
11
orthoses
10
fiber custom
8
custom dynamic
8
individuals lower
8

Similar Publications