A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessment of Inter- and Intrasurgeon Variability in Preoperative Planning of Reverse Shoulder Arthroplasty: A Multicenter Evaluation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

 To evaluate the intra and intersurgeon variability regarding the positioning and selection of implants in reverse shoulder arthroplasty.  A cross-sectional study assessed computed tomography images of the shoulder joint of patients diagnosed with degenerative joint diseases. The study team included seven specialists in shoulder surgery, representing six different institutions. Surgeons were instructed to plan all cases twice, and then we evaluated inter- and intrasurgeon variability.  The interclass correlation for version and inclination showed low agreement concerning inclination (0.26), and moderate agreement for version (0.73) and graft selection (0.54). The intrasurgeon evaluation revealed a moderate correlation for version (0.55), inclination (0.58), and implant selection (0.46), while for lateralization the correlation was high (0.77).  This comparative study of preoperative planning by different surgeons showed the lack of consensus on implant positioning parameters during reverse shoulder arthroplasty planning. However, most surgeons tend to plan for zero degrees of version and inclination.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11663061PMC
http://dx.doi.org/10.1055/s-0044-1788783DOI Listing

Publication Analysis

Top Keywords

reverse shoulder
12
shoulder arthroplasty
12
inter- intrasurgeon
8
intrasurgeon variability
8
preoperative planning
8
correlation version
8
version inclination
8
planning surgeons
8
shoulder
5
assessment inter-
4

Similar Publications