Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To develop and validate a novel analytical approach simplifying , , proton density (PD), and off-resonance quantifications from phase-cycled balanced steady-state free precession (bSSFP) data. Additionally, to introduce a method to correct aliasing effects in undersampled bSSFP profiles.

Theory And Methods: Off-resonant-encoded analytical parameter quantification using complex linearized equations (ORACLE) provides analytical solutions for bSSFP profiles. which instantaneously quantify , , proton density (PD), and . An aliasing correction formalism was derived to allow undersampling of bSSFP profiles. ORACLE was used to quantify , , PD, / , and based on fully sampled ( ) bSSFP profiles from numerical simulations and 3T MRI experiments in phantom and 10 healthy subjects' brains. Obtained values were compared with reference scans in the same scan session. Aliasing correction was validated in subsampled ( ) bSSFP profiles in numerical simulations and human brains.

Results: ORACLE quantifications agreed well with input values from simulations and phantom reference values (R = 0.99). In human brains, and quantifications when compared with reference methods showed coefficients of variation below 2.9% and 3.9%, biases of 182 and 16.6 ms, and mean white-matter values of 642 and 51 ms using ORACLE. The quantification differed less than 3 Hz between both methods. PD and maps had comparable histograms. The maps effectively identified cerebrospinal fluid. Aliasing correction removed aliasing-related quantification errors in undersampled bSSFP profiles, significantly reducing scan time.

Conclusion: ORACLE enables simplified and rapid quantification of , , PD, and from phase-cycled bSSFP profiles, reducing acquisition time and eliminating biomarker maps' coregistration issues.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.30388DOI Listing

Publication Analysis

Top Keywords

bssfp profiles
24
proton density
12
aliasing correction
12
oracle analytical
8
analytical approach
8
density off-resonance
8
phase-cycled balanced
8
balanced steady-state
8
steady-state free
8
free precession
8

Similar Publications

Quantitative susceptibility mapping in the human brain at 7T with phase-cycled balanced SSFP.

Magn Reson Med

October 2025

Department of Diagnostic, Interventional and Pediatric Radiology (DIPR), Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Purpose: To demonstrate the feasibility of QSM and to show the potential of simultaneous , , and proton density (PD) mapping in the human brain at 7T based on phase-cycled balanced SSFP (bSSFP) MRI.

Methods: An algorithm was developed to estimate off-resonance frequency in multi-compartment scenarios by combining elliptic phase-cycled bSSFP signal fitting with dictionary matching. Phase-cycled bSSFP-based tissue phase and susceptibility maps were compared with multi-echo gradient-echo (MEGRE)-based maps in the brains of eight healthy subjects at 7T.

View Article and Find Full Text PDF

Background: Although balanced steady-state free-precession (bSSFP) cines provide excellent contrast for morpho-functional cardiac evaluation, the fluctuating myocardial cine signal intensity (mcSI) is rarely used diagnostically. These mcSI fluctuations were related to through-plane motion but the impact of this motion remains unclear. We aim to characterize the mid-ventricular pre- and postcontrast bSSFP cyclic mcSI fluctuations in healthy subjects and compare these to Bloch simulations incorporating through-plane motion.

View Article and Find Full Text PDF

Purpose: To develop and validate a novel analytical approach simplifying , , proton density (PD), and off-resonance quantifications from phase-cycled balanced steady-state free precession (bSSFP) data. Additionally, to introduce a method to correct aliasing effects in undersampled bSSFP profiles.

Theory And Methods: Off-resonant-encoded analytical parameter quantification using complex linearized equations (ORACLE) provides analytical solutions for bSSFP profiles.

View Article and Find Full Text PDF

Purpose: Balanced steady-state free precession (bSSFP) imaging is susceptible to outflow effects where excited spins leaving the slice as part of the blood stream are misprojected back onto the imaging plane. Previous work proposed using slice-encoding steps to localize these outflow effects from corrupting the target slice, at the expense of prolonged scan time. This present study extends this idea by proposing a means of significantly reducing most of the outflowing signal from the imaged slice using a coil localization method that acquires a slice-encoded calibration scan in addition to the 2D data, without being nearly as time-demanding as our previous method.

View Article and Find Full Text PDF

Background: Simultaneous multi-slice (SMS) bSSFP imaging enables stress myocardial perfusion imaging with high spatial resolution and increased spatial coverage. Standard parallel imaging techniques (e.g.

View Article and Find Full Text PDF