Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Rationale And Objectives: To investigate the effect of ComBat harmonization on the stability of myocardial radiomic features derived from multi-energy CT reconstructions.

Materials And Methods: A retrospective study was conducted on 205 patients who underwent dual-energy chest CTA at a single center. The data was reconstructed into multiple spectral reconstructions (mixed energy simulating standard 120 Kv acquisition and monoenergetic images ranging from 40 to 190 keV in increments of 10). The left ventricle myocardium was segmented using semiautomated software (Syngo.Via FRONTIER, version 5.0.2; Siemens). Radiomic features were extracted from multiple spectral reconstructions (batches). The consistency of these radiomics features across different batches was evaluated with and without ComBat harmonization using Cohen's d and Principal component analysis (PCA). Both parametric and nonparametric ComBat methods were considered.

Results: Without any ComBat technique, 43.40% of features remained consistent across all multienergy reconstructions. Applying ComBat harmonization increased this consistency to 98.37% with parametric empirical bayes (EB) ComBat and EB M-ComBat, and to 91.52% and 92.33% with nonparametric EB ComBat and nonparametric EB M-ComBat, respectively. PCA without ComBat revealed noticeable differences in the first two principal components between batches, indicating a batch effect or unstable radiomic features. Following ComBat harmonization, the principal components showed more consistency between batches, demonstrating radiomics feature stability between batches.

Conclusion: ComBat harmonization enhanced the consistency of radiomic features from multi-energy CT data. Integrating ComBat harmonization may lead to more reproducible results in multienergy CT radiomics studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2024.111891DOI Listing

Publication Analysis

Top Keywords

combat harmonization
28
radiomic features
16
combat
12
multiple spectral
8
spectral reconstructions
8
nonparametric combat
8
principal components
8
harmonization
7
features
6
addressing inter-reconstruction
4

Similar Publications

Introduction: Despite increased national and international funding to combat the human immunodeficiency virus (HIV) pandemic, prison health services remain underfunded, resulting in poor HIV management among inmates. This study assessed viral suppression rates among HIV-positive inmates across four central prisons in Cameroon to evaluate the effectiveness of antiretroviral therapy (ART) in these settings.

Methodology: This cross-sectional study included four central prisons-prisons A, B, C, and D-each located in different regions of Cameroon.

View Article and Find Full Text PDF

Neuroimaging is vital in quantifying brain atrophy due to typical aging and due to neurodegenerative diseases. To collect large samples necessary to model lifespan brain development, research consortiums aggregate images acquired across multiple study sites. Previous studies have demonstrated that this multi-site study design can lead to site-related bias, necessitating harmonization of these "site effects".

View Article and Find Full Text PDF

Harmonizing multisite functional magnetic resonance imaging (fMRI) data is crucial for eliminating site-specific variability that hinders the generalizability of machine learning models. Traditional harmonization techniques, such as ComBat, depend on additive and multiplicative factors, and may struggle to capture the non-linear interactions between scanner hardware, acquisition protocols, and signal variations between different imaging sites. In addition, these statistical techniques require data from all the sites during their model training which may have the unintended consequence of data leakage for ML models trained using this harmonized data.

View Article and Find Full Text PDF

Background: The increased use of CT imaging has elevated the incidental detection of renal masses, necessitating accurate differentiation between benign and malignant nodules. Radiomics offers potential for improved diagnostics; however, it is limited by variability in imaging parameters such as slice thickness, highlighting the need for effective harmonization techniques.

Purpose: The purpose of this study is to conduct a comprehensive radiomics analysis, evaluating the impact of slice thickness in distinguishing between kidney cysts and tumors using machine learning techniques, thus contributing to more precise and effective patient management strategies.

View Article and Find Full Text PDF

Subcortical brain volume variations in autistic individuals across the lifespan.

Mol Autism

September 2025

Neurocognitive and Behavioral Development Laboratory, University of Florida, 1864 Stadium Road, 146 FLGym, PO Box 118205, Gainesville, FL, 32611-8205, USA.

Background: Structural alterations in subcortical brain regions-including the amygdala, hippocampus, basal ganglia, and cerebral ventricles-have been linked to various clinical features of autism spectrum disorder (ASD). However, volumetric features among these regions in autistic individuals across the lifespan remain poorly understood. This cross-sectional study aimed to investigate age-associated volumetric deviations in these clinically implicated subcortical regions of autistic individuals and neurotypical controls, and to examine the structural interrelationships within each group.

View Article and Find Full Text PDF