Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: We captured continuous glucose monitoring (CGM) metrics from a large online survey of adults with type 1 diabetes to determine how glycemic outcomes varied by insulin delivery form.

Research Design And Methods: Adults with type 1 diabetes from the T1D Exchange Registry/online communities completed the survey and contributed retrospective CGM data for up to 1 year. Self-reported glycemic outcomes and CGM measures were described overall and by insulin delivery method.

Results: The 926 participants completed the survey and provided CGM data. Mean ± SD age was 41.9 ± 15.7 years, and 50.8% reported using automated insulin delivery (AID). While AID users spent more time in range, 27.9% did not achieve time in range targets, 15.5% reported severe hypoglycemic events (SHEs), and 16.0% had CGM-detected level 2 hypoglycemic events.

Conclusions: Despite use of diabetes technologies, many individuals are unable to achieve glycemic targets and experience severe hypoglycemia, highlighting the need for novel treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11770157PMC
http://dx.doi.org/10.2337/dc24-1474DOI Listing

Publication Analysis

Top Keywords

insulin delivery
16
cgm data
12
adults type
12
type diabetes
12
glycemic targets
8
severe hypoglycemia
8
glycemic outcomes
8
completed survey
8
time range
8
cgm
5

Similar Publications

Current status of Liraglutide delivery systems for the management of type 2 diabetes mellitus.

Drug Deliv Transl Res

September 2025

Department of Pharmacy, Birla Institute of Technology and Science, Pilani, Pilani Campus, Vidya Vihar, Pilani, Rajasthan, 333031, India.

Diabetes is a metabolic disorder of increasing global concern. Characterized by constantly elevated levels of glucose, severe β-cell dysfunction, and insulin resistance, it is the cause of a major burden on patients if not managed with therapeutic and lifestyle changes. The human body is slowly developing tolerance to many marketed antidiabetic drugs and the quest for the discovery of newer molecules continues.

View Article and Find Full Text PDF

Aims: Preterm delivery (PTD) is a leading cause of neonatal morbidity and mortality. Accurate prediction is crucial for optimizing clinical outcomes, particularly in women with a short cervix. Although fetal fibronectin (FFN) is widely used to predict PTD, placental alpha-microglobulin-1 (PAMG-1) has gained attention for its potential to improve predictive accuracy.

View Article and Find Full Text PDF

Obesity is intricately linked to various metabolic diseases; however, some individuals maintain metabolic health despite being classified as obese. A critical factor underlying this paradox is the expansion of white adipose tissue (WAT), which can occur through two mechanisms: hypertrophy (the enlargement of existing fat cells) and hyperplasia (the formation of new fat cells from adipocyte precursor cells, or APCs). Hyperplasia is regarded as a healthier mode of WAT expansion, as it tends to reduce inflammation and protect against insulin resistance.

View Article and Find Full Text PDF

CamAPS FX is a customizable hybrid closed-loop app with a default target glucose of 105 mg/dL. The personal glucose target is user-adjustable in 1 mg/dL increments between 80 and 198 mg/dL in 30-min segments over 24 h. We assessed the impact of different personal glucose targets on glycemic control during real-world use of CamAPS FX in different age-groups.

View Article and Find Full Text PDF

The purpose of this paper is to describe the development of a low-cost insulin infusion pump software simulator. The simulator was built using Java programming language and replicates the interface and functions of a real low-cost insulin infusion pump currently under development. Potential users participated in a remote session, and assessment was conducted using a standard usability scale (SUS).

View Article and Find Full Text PDF