A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Biofluorometric Acetone Gas Sensor of Sub-ppbv Level Sensitivity. | LitMetric

Biofluorometric Acetone Gas Sensor of Sub-ppbv Level Sensitivity.

Anal Chem

Department of Biomedical Devices and Instrumentation, Laboratory for Biomaterials and Bioengineering, Institute of Integrated Research, Institute of Science Tokyo, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.

Published: December 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Acetone gas in exhaled breath and skin gas is produced when fatty acids are used as an energy source in the body. The selective and sensitive continuous measurement of acetone gas would be useful for the early screening of diabetes mellitus, a condition characterized by increased fatty acid metabolism. In particular, there is a growing need for acetone gas sensors that enable the wearable measurement of trace concentrations of acetone gas emitted through the skin. In this study, we improved the sensor's sensitivity by optimizing the fluorescence measurement system and flow cell of a previously developed biofluorometric acetone gas sensor (bio-sniffer) using secondary alcohol dehydrogenase. To evaluate the performance of the improved acetone bio-sniffer, we constructed a dilution system to prepare acetone gas at subparts per billion by volume (ppbv) levels and verified its accuracy using gas chromatography-mass spectrometry. As a result, the dilution system was able to prepare 0.1 ppbv of acetone gas with a coefficient of variation of 5%. The improved acetone bio-sniffer demonstrated quantitative characteristics in the concentration range of 0.5-1000 ppbv, with a lower limit of quantification that was 40 times better than that of the conventional acetone bio-sniffer. In the future, this system is expected to be used for continuous measurement of acetone gas released through the skin.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.4c03816DOI Listing

Publication Analysis

Top Keywords

acetone gas
36
acetone bio-sniffer
12
gas
11
acetone
11
biofluorometric acetone
8
gas sensor
8
continuous measurement
8
measurement acetone
8
improved acetone
8
dilution system
8

Similar Publications