98%
921
2 minutes
20
Purpose: To evaluate the reproducibility of important biomarkers like wall shear stress (WSS), pulse wave velocity (PWV), and net flow across two 4D flow MRI imaging protocols with different coverages: aorta-targeted 4D flow MRI (AT4D) and whole-heart 4D flow (WH4D) protocols.
Methods: Thirty-eight control subjects (43.2 ± 10.1 years old; 22 males) and ten patients (45.7 ± 8.9 years old; 7 males) with bicuspid aortic valve (BAV) were included. Each subject underwent AT4D and WH4D scans. Absolute WSS, PWV, and net flow were assessed for each patient across both protocols and compared using Bland-Altman analysis. Areas of elevated WSS were assessed for BAV patients across different WSS thresholds that define WSS to be elevated compared to a normal population average. A sensitivity analysis was conducted to determine the best WSS threshold at which WH4D-derived areas most closely resemble AT4D-derived areas. Inter-rater reproducibility was evaluated in twenty-four subjects.
Results: AT4D and WH4D PWV and WSS estimates demonstrated good agreement (PWV: -0.12 ± 1.84 m/s, p = 0.4; Median WSS: 0.06 ± 0.13 Pa, p < 0.01; Maximum WSS: 0.04 ± 0.27 Pa, p = 0.07). Good agreement was also found for AAo net flow (8.14 ± 24.86 mL/cycle, p < 0.01). PWV correlated with age across protocols (AT4D: r = 0.68, p < 0.01; WH4D: r = 0.72, p < 0.01). Sensitivity analysis identified a WSS threshold where WH4D-derived areas of elevated WSS most closely resembled AT4D-derived areas. Inter-rater assessment of the tested parameters resulted in a small mean difference percentage of < 3%.
Data Conclusion: PWV, WSS, and net flow demonstrated good agreement across protocols. The WSS threshold should be adjusted for WH4D estimates to optimally match AT4D-derived output. Reproducibility analysis showed good test-retest agreement. This study demonstrates the reproducibility of certain hemodynamic parameters across two 4D flow MRI protocol.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11995425 | PMC |
http://dx.doi.org/10.1007/s10554-024-03299-1 | DOI Listing |
Radiol Case Rep
November 2025
Department of Radiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan.
Congenital intrahepatic portosystemic shunts are uncommon vascular anomalies that can lead to hyperammonemia and liver dysfunction. We report a 48-year-old woman with a large intrahepatic shunt presenting with elevated blood ammonia and progressive hepatic atrophy. She underwent percutaneous coil-in-plug embolization using an Amplatzer Vascular Plug II filled with coils.
View Article and Find Full Text PDFCureus
August 2025
Department of Neurosurgery, The University of Osaka Graduate School of Medicine, Suita, JPN.
Fungal cerebral aneurysms, particularly those resulting from direct invasion by fungal sinusitis, are rare and often fatal when involving the cavernous segment of the internal carotid artery (ICA). We present a case of a ruptured fungal ICA aneurysm caused by sinusitis, successfully treated with parent artery occlusion (PAO). In this case, an 80-year-old woman presented with right ptosis, facial pain, and cranial nerve III, IV, and VI palsies.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
September 2025
From the Department of Interventional Radiology (Shuailong Shi, Shuhai Long, Ji Ma, Peijie Lu, Jie Yang, Ye Wang, Tengfei Li), The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China; The School of Life Science and Technology (Zhike Zhang), Xi'an Jiaotong University, Xi'an, China; an
Background And Purpose: Although high-resolution cone-beam computed tomography (HR-CBCT) is used for immediate evaluation of stent apposition, studies using this technique to evaluate flow diverter (FD) endothelialization during follow-up are limited. The study aims to investigate the potential of HR-CBCT in assessing FD endothelialization and identify factors influencing poor endothelialization.
Materials And Methods: The clinical and imaging data of patients with unruptured intracranial aneurysms (UIAs) treated by FDs from March 2019 to October 2023 were retrospectively analyzed.
Eur Heart J Cardiovasc Imaging
September 2025
Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Aims: Fetal circulation undergoes complex changes in congenital heart disease (CHD) that are challenging to assess with fetal echocardiography. This study aimed to assess clinical feasibility and diagnostic value of 4D flow cardiac magnetic resonance (CMR) in fetal CHD.
Methods And Results: Pregnant women in advanced third trimester pregnancy with fetal CHD were prospectively recruited for fetal CMR between 08/2021 and 11/2024.
J Cardiovasc Magn Reson
September 2025
Department of Magnetic Resonance Imaging, Fuwai Hospital and National Center for Cardiovascular Diseases, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing 100037, China; Key Laboratory of Cardiovascular Imaging, Chinese Academy of Medical Sciences, Beijing 100730, China.
Background: Conventional cardiac magnetic resonance (CMR) examinations require patients to repeatedly hold their breath, which can reduce examination efficiency and pose challenges for patients unable to do so. This study aimed to demonstrate the feasibility and effectiveness of a full free-breathing CMR protocol in clinical practice.
Methods: Patients prospectively enrolled in this study underwent a full free-breathing CMR exam on a 3T scanner between June 1 and June 30, 2024.