A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of different concentrations of calcium gluconate added in replacement fluid to maintain ionised calcium levels during therapeutic plasma exchange procedures. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Therapeutic plasma exchange (TPE) is generally well tolerated but Anticoagulant Citrate Dextrose Solution A (ACD-A) can cause citrate mediated hypocalcaemia so, adding calcium gluconate to the replacement fluid is effective in preventing this complication. We aimed to compare the effect of different concentrations of 10 % calcium gluconate (9.3 mg of elemental calcium/100 ml Vs 18.6 mg of elemental calcium/100 ml) added to 5 % Human Serum Albumin (HSA) on intraprocedural and post procedural ionised calcium (iCa2+) levels in patients with neurological conditions undergoing TPE.

Material And Methods: This study comprised of 100 TPE procedures divided into two groups of 50 each. In group 1, 5 ml of 10 % calcium gluconate was added in 500 ml of 5 % HSA (9.3 mg of elemental calcium/100 ml) and in group 2, 10 ml of 10 % calcium gluconate was added (18.6 mg of elemental calcium/100 ml) in 5 % of HSA. Ionised calcium was noted-pre, intra and post-procedure and compared within the groups along with other procedural parameters and adverse events if any.

Results: We observed that mean intraprocedural ionised calcium levels were comparable (p = 0.579) in both the groups, but post-procedural iCa2+ levels significantly decreased (p = 0.003) in group-1 as compared to group-2. Symptomatic hypocalcaemia was seen in 14 % of patients group 1 compared to 2 % in group-2. Vasovagal reactions were 8 % in group-1 % and 2 % in group-2.

Conclusion: Prophylactic addition of 18.6 mg of elemental calcium/100 ml of 5 % HSA is safe to maintain levels of iCa2+ throughout the procedure with lower chances of adverse events related to hypocalcaemia.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.transci.2024.104039DOI Listing

Publication Analysis

Top Keywords

calcium gluconate
20
elemental calcium/100 ml
20
ionised calcium
16
10 % calcium
12
186 mg elemental
12
calcium/100 ml 5 %
12
5 % hsa
12
calcium
9
gluconate replacement
8
replacement fluid
8

Similar Publications