A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Usefulness of a dedicated laser-cut metal stent with an anchoring hook and thin delivery system for EUS-guided hepaticogastrostomy in malignant biliary obstruction: a prospective multicenter trial (with video). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: EUS-guided hepaticogastrostomy (EUS-HGS) carries a risk of serious adverse events (AEs). A newly designed, partially covered laser-cut stent with antimigration anchoring hooks and a thin tapered tip (7.2F), called a Hook stent (Zeon Medical, Tokyo, Japan), has been developed to prevent serious AEs associated with EUS-HGS. The present prospective multicenter clinical trial evaluated the efficacy and safety of the Hook stent for EUS-HGS after failure of ERCP in patients with unresectable malignant biliary obstruction.

Methods: The primary endpoint was the rate of clinical success, and secondary endpoints were the rates of technical success, AEs, recurrent biliary obstruction (RBO), procedure success without using a tract dilation device, reintervention for RBO, time to RBO, and overall survival (OS).

Results: Thirty-eight patients underwent EUS-HGS using the Hook stent. The technical and clinical success rates in patients undergoing EUS-HGS were 100% and 92.1%, respectively. The procedure success rate without using a tract dilation device was 94.7%. Four patients (10.5%) developed early AEs, but there were no severe AEs such as stent migration. RBO developed in 26.3% of patients. Reintervention for RBO had a 100% success rate. The median time to RBO was not reached, and the median OS was 191 days.

Conclusions: EUS-HGS using the Hook stent demonstrated a high clinical success rate, low rate of early AEs, and an acceptable stent patency. The Hook stent is safe and feasible for use in patients undergoing EUS-HGS. (Clinical trial registration number: jRCT2052210020.).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2024.11.005DOI Listing

Publication Analysis

Top Keywords

hook stent
20
clinical success
12
success rate
12
stent
9
eus-guided hepaticogastrostomy
8
malignant biliary
8
biliary obstruction
8
prospective multicenter
8
clinical trial
8
procedure success
8

Similar Publications