98%
921
2 minutes
20
(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4° ± 1.7°) compared to the ASIS (2.8° ± 1.7°, = 0.17) and APP method (3.7° ± 2.1°, < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4° ± 1.8°) in contrast to the ASIS (3.9° ± 3.2°, = 0.005) and APP method (9.1° ± 6.2°, < 0.001). (4) Conclusion: A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11548659 | PMC |
http://dx.doi.org/10.3390/s24217092 | DOI Listing |
J Orthop Sci
September 2025
American Hip Institute Research Foundation, Chicago, IL 60018, USA; American Hip Institute, Chicago, IL 60018, USA. Electronic address:
Background And Objective: With obese individuals experiencing osteoarthritis (OA) at early stages of life, hip resurfacing (HR) has emerged as an alternative to arthroplasty. The purpose is to conduct a short-term analysis on patients with obesity who underwent primary HR for OA compared to a benchmark control group of non-obese patients.
Materials And Methods: Patients with a body mass index (BMI) ≥ 30 kg/m2 who underwent HR from 2010 to 2021 were eligible for inclusion.
Int J Surg
September 2025
Shanghai Key Laboratory of Orthopaedic Implants, Department of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
Background: Precise acetabular cup placement in total hip arthroplasty (THA) heavily relies on surgeons' visual judgment of angles. However, whether inherent visual angle misperception among surgeons affects surgical outcomes remains unclear. This study is the first to reveal that surgeons universally exhibit visual angle misperception, a key factor causing the cup implant positioning deviations in THA.
View Article and Find Full Text PDFActa Ortop Mex
September 2025
Servicio de Ortopedia y Traumatología, Hospital de San Rafael, Hospitales Pascual. Cádiz, España.
Introduction: anatomical deformities such as developmental dysplasia of the hip (DDH) and Perthes disease represent a challenge for reconstruction. The use of 3D-printed models can be helpful for assessing the deformity, bone mass, implant size, and orientation.
Objectives: to prospectively evaluate the outcomes of 3D simulation in primary total hip arthroplasty.
Arch Orthop Trauma Surg
September 2025
Division of Orthopaedics and Traumatology, Cantonal Hospital Winterthur, Winterthur, Switzerland.
Background: Accurate acetabular cup orientation in total hip arthroplasty (THA) is crucial for successful outcomes. Intraoperative fluoroscopy may be used to evaluate acetabular cup placement. This study aimed to evaluate the accuracy of purely visual estimation of cup inclination and anteversion using intraoperative fluoroscopy, considering different surgeon experience levels and cup designs.
View Article and Find Full Text PDFFront Surg
August 2025
Department of Orthopedics, The First Hospital of Jilin University, Changchun, Jilin, China.
Background: Acetabular reconstruction is often challenging in revision hip arthroplasty, especially in the face of moderate to severe acetabular bone deficiency. In some severe bone defects, double-metal tantalum cups can improve the contact area between bone and implants, increase the surface area for bone ingrowth, and better restore the anatomical position of the acetabulum. Furthermore, with a good press-fit, the auxiliary screw has a minimal effect on acetabular cup stability.
View Article and Find Full Text PDF