Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Closed system transfer devices (CSTD) help to reduce the exposure of healthcare professionals to hazardous drugs. They may be used in stability studies conducted on anticancer drugs. During a stability study about polyolefin bags of gemcitabine, Tevadaptor® device was suspected of causing a bias in the evaluation of the concentrations of the first aliquots extracted from the bags.
Objective: The objectives are to determine whether the use of a CSTD to prepare a drug solution and to withdraw it from a bag can interfere on the measured concentration compared to the expected one and to suggest hypothesis to explain the phenomenon.
Method: In the first experiment, three polyolefin bags of gemcitabine (5.4 mg/mL) were prepared under aseptic conditions using the Tevadaptor Luer Lock Adaptor®. The day of preparation, five aliquots of 3.8 ml each were sequentially withdrawn from each polyolefin bag using the same device. After one day, a new aliquot was withdrawn from each bag. In the second experiment, three polyolefin bags of gemcitabine (5.4 mg/ml) were prepared under aseptic conditions using a needle. One aliquot was extracted using a needle after the preparation from each bag, and another aliquot was extracted after one day. The concentrations of all aliquots were measured by liquid chromatography coupled to a photodiode array detector during the same run.
Results And Discussion: The concentrations of the first aliquots extracted on day zero from the polyolefin bags using the Tevadaptor Luer Lock Adaptor® exhibit an overestimation of 26% ([95%CI: 23%-29%] P<0.001) compared to the others. Overestimation is not found for subsequent aliquots, or while using a needle to bypass the Tevadaptor® device.
Conclusion: This case highlights the bias that may arise when using CSTDs in stability studies. They should be used with comprehensive understanding of their technical specifications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11536552 | PMC |
http://dx.doi.org/10.1177/87551225241285319 | DOI Listing |