A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Fluorescence-guided tumor visualization of colorectal cancer using tumor-initiating probe yellow in preclinical models. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Fluorescence-guided surgery has emerged as an innovative technique with promising applications in the treatment of various tumors, including colon cancer. Tumor-initiating probe yellow (TiY) has been discovered for identifying tumorigenic cells by unbiased phenotypic screening with thousands of diversity-oriented fluorescence library (DOFL) compounds in a patient-derived lung cancer cell model. This study demonstrated the clinical feasibility of TiY for tumor-specific fluorescence imaging in the tissues of patients with colorectal cancer (CRC). To evaluate the efficacy of TiY in tumor imaging, surgical specimens were obtained, consisting of 36 tissues from 18 patients with CRC, for ex vivo molecular fluorescence imaging, histology, and immunohistochemistry. Orthotopic and chemically induced CRC mice models were administered TiY topically, and distinct tumor lesions were observed in 10 min by real-time fluorescence colonoscopy and ex vivo imaging. In a hepatic metastasis mouse model using splenic injection, TiY accumulation was detected in metastatic liver lesions through fluorescence imaging. Correlation analysis between TiY intensity and protein expression, assessed via immunohistochemistry and Western blotting, revealed a positive correlation between TiY and vimentin and Zeb1, which are known as epithelial-mesenchymal transition (EMT) markers of cancers. A comparative analysis of TiY with other FDA-approved fluorescence probes such as ICG revealed greater quantitative differences in TiY fluorescence intensity between tumor and normal tissues than those observed with ICG. Altogether, these results demonstrated that TiY has a strong potential for visualizing CRC by fluorescence imaging in various preclinical models, which can be further translated for clinical use such as fluorescence-guided surgery. Furthermore, our data indicate that TiY is preferentially uptaken by cells with EMT induction and progression, and overexpressing vimentin and Zeb1 in patients with CRC.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11542034PMC
http://dx.doi.org/10.1038/s41598-024-76312-1DOI Listing

Publication Analysis

Top Keywords

fluorescence imaging
16
tiy
11
colorectal cancer
8
cancer tumor-initiating
8
tumor-initiating probe
8
probe yellow
8
preclinical models
8
fluorescence-guided surgery
8
fluorescence
8
tissues patients
8

Similar Publications