A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparative analysis of rotary versus manual instrumentation in paediatric pulpectomy procedures: A systematic review and meta-analysis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The use of rotary file in permanent teeth is well-documented, but there is limited scientific evidence for its effectiveness in primary teeth. A meta-analysis was conducted to compare rotary and manual tools in primary tooth pulpectomy procedures. Ten databases were searched from 2000 to 2024 to find relevant literature. The Cochrane Risk of Bias (ROB) tool assessed bias in randomised control trials. STATA software version 18 conducted the meta-analysis. A random-effects model was used for instrumentation time and obturation quality evaluation while sensitivity analysis followed high heterogeneity detection. Twenty RCTs were included after screening 723 studies. Publication bias and heterogeneity were found for instrumentation time, leading to removal of nine studies. Significant difference in mean instrumentation time (1.42) was noted. Obturation quality assessment showed an odds ratio of 1.82. Use of rotary instrumentation yielded superior outcomes compared with manual instrumentation for pulpectomy for primary teeth.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aej.12899DOI Listing

Publication Analysis

Top Keywords

instrumentation time
12
manual instrumentation
8
pulpectomy procedures
8
primary teeth
8
obturation quality
8
instrumentation
6
comparative analysis
4
rotary
4
analysis rotary
4
rotary versus
4

Similar Publications