A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Inter-laboratory harmonization of microsphere immunoassays for SARS-CoV-2 antibody detection in dried blood spots and oral fluids. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dried blood spots (DBS) and oral fluids (OF) are easily attainable biospecimen types that have enabled population scale antibody monitoring for SARS-CoV-2 exposure and vaccination. However, the degree to which the two different biospecimen types can be used interchangeably remains unclear. To begin to address this question, we generated contrived DBS (cDBS) and OF (cOF) from serum panels from SARS-CoV-2 infected, vaccinated, and uninfected individuals. The contrived samples were evaluated using SARS-CoV-2 multiplexed microsphere immunoassays (MIAs) at two different institutions. Intra-laboratory tests revealed near perfect agreement between cDBS and cOF for N and S antigens, as evidenced by κ = 0.97-1 and 98%-100% agreement. Inter-laboratory comparisons were equally robust for both N (κ = 0.94-0.96; 97.5%-98 % agreement) and S (κ = 0.98 -1.0; 99.0%-100%). Furthermore, assays were transferred between labs, including methods and reagents, and a subset of cDBS and cOF samples (n = 52) were tested. Qualitative concordance remained high (κ = 0.94-1.0; 97.5%-100% agreement), confirming that integrity of the assays is retained upon transfer. In summary, our results provide evidence that DBS and OF can be used interchangeably across laboratories and institutions for the qualitative assessment of SARS-CoV-2 antibody determinations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11527004PMC
http://dx.doi.org/10.1101/2024.10.19.619238DOI Listing

Publication Analysis

Top Keywords

cdbs cof
12
microsphere immunoassays
8
sars-cov-2 antibody
8
dried blood
8
blood spots
8
oral fluids
8
biospecimen types
8
sars-cov-2
5
inter-laboratory harmonization
4
harmonization microsphere
4

Similar Publications