A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Revisiting the diagnostic performance of exosomes: harnessing the feasibility of combinatorial exosomal miRNA profiles for colorectal cancer diagnosis. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The challenges associated with liquid biopsy of colorectal cancer (CRC) are closely linked to the substantial variations observed in gene expression profiles among patients. This variability complicates the selection of an ideal biomarker for accurate diagnosis. In this report, we propose that employing a combination of miRNAs offers a better change for enhancing the accuracy of CRC diagnosis compared to solely relying on single miRNAs. As an illustrative example, we measured 9 miRNAs from 45 patient samples (comprising 31 CRC cases and 14 healthy controls) via RT-qPCR. We then utilized two methods: (1) LASSO regression for marker ranking and (2) linear discriminant analysis (LDA) to identify the optimal weighted combination of multiple markers. Our data indicates that combination of triple markers, selected based on their ranking, exhibited the highest diagnostic performance, including a sensitivity of 93.6% (95% confidence interval, CI 79.3-98.9%), specificity of 100% (CI 78.5-100.0%), positive predictive value (PPV) of 100%, negative predictive value (NPV) of 87.5%, and an overall accuracy of 95.6%. In contrast, the diagnostic performance of each individual miRNA used in the triple marker combination ranged from 53.3 to 80.0% in accuracy. While we acknowledge the need for further extensive studies involving larger patient cohorts and the consideration of additional miRNA candidates, our research undeniably highlights the potential of combining multiple markers as a robust methodology for identifying biomarkers among heterogeneous patient profiles.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525371PMC
http://dx.doi.org/10.1007/s12672-024-01481-4DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
12
colorectal cancer
8
multiple markers
8
revisiting diagnostic
4
performance exosomes
4
exosomes harnessing
4
harnessing feasibility
4
feasibility combinatorial
4
combinatorial exosomal
4
exosomal mirna
4

Similar Publications