A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Multifaceted Control Interventions for Healthcare-associated Infections in a Kidney Transplant Intensive Care Unit: Clinical Outcome Improvement and Bundle Adherence. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Healthcare-associated infections (HAIs) are preventable complications that overwhelm the healthcare system. The implementation of multifaceted control intervention actions in the intensive care setting modifies clinical outcomes, but its effectiveness has not been specifically investigated for high-risk patients, such as kidney transplant recipients (KTRs).

Methods: This observational retrospective natural experiment evaluated the effectiveness of multifaceted control interventions (bundles) in reducing HAIs in a KTR intensive care unit. We also measured the bundle adherence rate during 16 mo in the after era.

Results: We included 1257 KTRs, 684 before and 573 in the postintervention period. After the bundle implementation, the incidence density of device-associated HAIs decreased from 8.5 to 3.9 per 1000 patient-days (relative risk [RR] = 0.46; 95% confidence interval [CI], 0.25-0.85;  = 0.01), primarily because of the reduction in central line-associated bloodstream infection from 8.0 to 3.4 events per 1000 catheter-days (RR = 0.43; 95% CI, 0.22-0.83;  = 0.012). Reductions in catheter-associated urinary tract infection (2.5 versus 0.6 per 1000 catheter-days; RR = 0.22; 95% CI, 0.03-1.92;  = 0.17) and ventilator-associated pneumonia (3.4 versus 1.0 per 1000 ventilator-days; RR = 0.29; 95% CI, 0.03-2.63;  = 0.27) were not significant. Central venous ( = 0.53) and urinary catheter ( = 0.47) insertion adherence were stable during 16 mo, whereas central venous ( < 0.001) and urinary catheter ( = 0.004) maintenance gradually increased. Finally, ventilator-associated pneumonia prevention bundle adherence slightly decreased over time ( = 0.06).

Conclusions: The implementation of comprehensive multifaceted control intervention actions in an intensive care unit dedicated to KTR care was effective in significantly reducing device-associated infections. The impact was in line with the reductions observed in populations that have not undergone transplantation, underscoring the effectiveness of these interventions across different patient groups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11521075PMC
http://dx.doi.org/10.1097/TXD.0000000000001718DOI Listing

Publication Analysis

Top Keywords

multifaceted control
12
intensive care
12
control interventions
8
healthcare-associated infections
8
kidney transplant
8
care unit
8
bundle adherence
8
1000 catheter-days
8
versus 1000
8
central venous
8

Similar Publications