Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To evaluate the effect of a staining solution on the color stability of resins for complete dentures produced with conventional and digital technologies.
Materials And Methods: A total of 60 resin specimens were prepared and divided into six groups of 10 specimens each: Probase Hot (PH; Ivoclar), IvoBase CAD (IBC; Ivoclar), Ivotion Dent (ID; Ivoclar), Ivotion Dent Multi (IDM; Ivoclar), Dima Print Denture Base (DPDB; Kulzer), and Dima Print Denture Teeth (DPDT; Kulzer). One surface of each specimen was polished following the manufacturer's instructions. The CIELab color differences were evaluated before and after 28 days of immersion in a coffee solution and measured as ∆E using two dental spectrophotometers. One specimen for each group was selected for scanning electron microscopy (SEM) analysis at baseline and at 28 days.
Results: Data analysis was performed with Kruskal-Wallis test and post-hoc Dunn test for comparison. Regarding specimens analyzed with VITA Easyshade, IDM white zone (polished and unpolished) scored higher (∆E = 0.87 and ∆E = 1.15, respectively). All milled samples (IBC, ID, IDM pink zone), scored significantly higher compared to PH and DPDT. Regarding SpectroShade, IDM pink zone performed better for both polished and unpolished specimens (∆E = 1.57 and ∆E = 2.07, respectively). ID demonstrated a statistically higher color stability compared to PH and DPDT. Regarding SEM analysis, any difference in surface morphology was observed between baseline and 28-day immersion analyses.
Conclusions: Color stability was significantly higher in resin specimens obtained with digital technologies compared to conventional resin specimens afterimmersion in a staining solution.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/ijp.9191 | DOI Listing |