Background: There are guidelines recommending the use of Indwelling pleural catheter (IPC), but there is no established consensus or guidelines regarding the modality of drainage post-IPC insertion. We have devised a novel drainage technique that combines the advantages of both aggressive and symptom-guided drainage.
Method: This was a prospective intervention trial in which patients with malignant pleural effusion, drained with IPC, were initially given one week of 'high-intensity' drainage on an outpatient basis using a low-pressure suction pump, followed by symptom-based home drainage using vacuum bottles. Patients were assessed for improvement in breathlessness, the number of autos pleurodesis, and the number of vacuum bottles consumed.
Results: A total of 25 patients with malignant pleural effusion who satisfied the inclusion criteria were selected. The mean breathlessness as per the visual analogue scale (VAS) was 87 before the insertion of IPC, which decreased to 48.2 immediately after IPC insertion and drainage. The 'high-intensity' drainage was able to maintain this fall in VAS. Thirteen patients (52%) achieved pleurodesis, of which 10 achieved pleurodesis after 5 weeks of IPC insertion, and 3 achieved pleurodesis after 7 weeks of IPC insertion. Eleven patients (44%) had the IPC in situ until death. One patient had the IPC removed due to empyema. None of the 10 patients who achieved pleurodesis within 5 weeks of IPC insertion had to use vacuum bottles at home for 'symptom-guided' fluid drainage.
Conclusion: This novel method of draining malignant pleural effusion brought about symptomatic improvement, increase auto-pleurodesis, and thereby reduce the number of vacuum bottles consumed in the study population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11627351 | PMC |
http://dx.doi.org/10.4103/lungindia.lungindia_286_24 | DOI Listing |
Maedica (Bucur)
June 2025
Italian Scientific Society of Oxygen Ozone Therapy (SIOOT) and High Master School of Oxygen Ozone Therapy, University of Pavia, Pavia, Italy.
This study investigates the safety implications of using glass bottles versus PVC, DEHP-free plastic bags for autologous blood collection in major autohaemotherapy with oxygen-ozone (O 2 -O 3 -MAHT). Concerns have arisen regarding increased haemolysis when blood is collected in glass containers, particularly due to high shear stress, surface irregularities and turbulence associated with vacuum-based collection. Historical data from transfusion medicine already established that glass induces higher red blood cell (RBC) rupture rates, a finding confirmed through mathematical modelling and simulations in this study.
View Article and Find Full Text PDFKorean J Helicobacter Up Gastrointest Res
December 2024
Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Objectives: To involve institutions without the ability to perform susceptibility testing, long-term storage of tissue sample is critical to isolate the bacteria in a central laboratory. The aim of the study was to investigate the feasibility of isolation and antibiotic susceptibility testing using rapidly frozen biopsy specimens collected from various institutions.
Methods: Eight institutions located in various regions of Korea participated in the study.
Vet Sci
April 2025
Department of Clinical Sciences, Colorado State University, Fort Collins, CO 80523, USA.
The discontinuation of commercially available saline and hypertonic saline wound dressings for the veterinary market has restricted options available to veterinary practitioners treating contaminated and infected wounds. Clinicians may manufacture their own homemade solutions in clinics or field settings to treat equine or livestock species; however, information is limited on whether autoclave sterilization is necessary or sufficient to eliminate bacterial growth in isotonic and concentrated salt solutions and how long they may subsequently be stored prior to use. The purpose of this study was to assess sterility of saline (0.
View Article and Find Full Text PDFJ Appl Lab Med
July 2025
Diagnostic Devices Research and Development, Labcorp, Pleasanton, CA, United States.
Background: The proliferation of decentralized sample collection models improves patient access and experience with laboratory medicine. However, many analytes have limited stability in liquid whole blood, serum, or plasma such that prompt transport under controlled temperature protection is crucial to analytical accuracy. Here we validate the Labcorp TrueTherm™ reusable shipper intended to thermally protect small volume specimens.
View Article and Find Full Text PDFANZ J Surg
March 2025
Department of Surgery, Eastern Health, Melbourne, Victoria, Australia.
Enteroatmospheric fistula is a severe complication associated with an open abdomen, and management of this can be challenging. This article describes a practical and accessible wound management option for enteroatmospheric fistula using a generic silicone bottle teat and vacuum-assisted closure dressing.
View Article and Find Full Text PDF