A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bionic Design of High-Performance Joints: Differences in Failure Mechanisms Caused by the Different Structures of Beetle Femur-Tibial Joints. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Beetle femur-tibial joints can bear large loads, and the joint structure plays a crucial role. Differences in living habits will lead to differences in femur-tibial joint structure, resulting in different mechanical properties. Here, we determined the structural characteristics of the femur-tibial joints of three species of beetles with different living habits. The tibia of Scarabaeidae and Cetoniidae slide through cashew-shaped bumps on both sides of the femur in a guide rail consisting of a ring and a cone bump. The femur-tibial joint of Buprestidae is composed of a conical convex tibia and a circular concave femur. A bionic structure design was developed out based on the characteristics of the structure of the femur-tibial joints. Differences in the failure of different joint models were obtained through experiments and finite element analysis. The experimental results show that although the spherical connection model can bear low loads, it can maintain partial integrity of the structure and avoid complete failure. The cuboid connection model shows a higher load-bearing capacity, but its failure mode is irreversible deformation. As key parts of rotatable mechanisms, the bionic models have the potential for wide application in the high-load engineering field.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11505458PMC
http://dx.doi.org/10.3390/biomimetics9100605DOI Listing

Publication Analysis

Top Keywords

femur-tibial joints
16
joints differences
8
differences failure
8
beetle femur-tibial
8
joint structure
8
living habits
8
femur-tibial joint
8
connection model
8
femur-tibial
6
joints
5

Similar Publications