A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Highly sensitive multiplexed colorimetric lateral flow immunoassay by plasmon-controlled metal-silica isoform nanocomposites: PINs. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Lateral flow assay (LFA) systems use metal nanoparticles for rapid and convenient target detection and are extensively studied for the diagnostics of various diseases. Gold nanoparticles (AuNPs) are often used as probes in LFAs, displaying a single red color. However, there is a high demand for colorimetric LFAs to detect multiple biomarkers, requiring the use of multicolored NPs. Here, we present a highly sensitive multiplexed colorimetric lateral flow immunoassay by multicolored Plasmon-controlled metal-silica Isoform Nanocomposites (PINs). We utilized the localized surface plasmon resonance effect to create multi-colored PINs by precisely adjusting the distance between the NPs on the surface of PINs through the controlled addition of reduced gold and silver precursors. Through simulations, we also confirmed that the distance between nanoparticles on the surface of PINs significantly affects the color and colorimetric signal intensity of the PINs. We achieved multicolored PINs that exhibit stronger colorimetric signals, offering a new solution for LFA detection with high sensitivity and a 33 times reduced limit of detection (LOD) while maintaining consistent size deviations within 5%. We expect that our PINs-based colorimetric LFA will facilitate the sensitive and simultaneous detection of multiple biomarkers in point-of-care testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11502615PMC
http://dx.doi.org/10.1186/s40580-024-00449-yDOI Listing

Publication Analysis

Top Keywords

lateral flow
12
highly sensitive
8
sensitive multiplexed
8
multiplexed colorimetric
8
colorimetric lateral
8
flow immunoassay
8
plasmon-controlled metal-silica
8
metal-silica isoform
8
isoform nanocomposites
8
nanocomposites pins
8

Similar Publications