Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
A sustainable alternative to conventional concrete involves using recycled aggregates (RA) instead of natural aggregates (NA) and incorporating wheat straw ash (WSA) as a partial replacement for Portland cement. The demand for high-performance concrete (HPC) is rising due to the need for architecturally complex structures and long-span bridges, but HPC's low ductility necessitates reinforcement. Waste tire steel fibers (WTSFs) are gaining popularity for their tensile strength. However, WSA-RA concrete's low early strength is a challenge. Chemical activators like sodium sulfate can enhance early-age strength. This study evaluated the durability and strength of fiber-reinforced concrete with both inactivated and activated WSA. Tests included compressive strength, indirect tensile strength, modulus of rupture (MOR), acid attack resistance, chloride penetration, sorptivity, and water absorption. Activated WSA-RA concrete showed significantly improved early strength. The mixture with 30% RA, 40% WSA, WTSFs, and activator exhibited the highest strength at 90 days. At 60% RA content, activated concrete with 40% WSA and 2.5% WTSFs outperformed the control. Durability was enhanced with a 14-17% reduction in water absorption and sorptivity and a 25.2% decrease in chloride penetration. Acid resistance improved by 26%. X-ray diffraction (XRD) confirmed these findings with elevated hydration product peaks. This study demonstrates that chemical activation of WSA optimizes the engineering properties of WSA-modified HPC with WTSFs and RA, providing a sustainable solution to their challenges.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11495566 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0311838 | PLOS |