98%
921
2 minutes
20
Background: Fundus vessel segmentation is vital for diagnosing ophthalmic diseases like central serous chorioretinopathy (CSC), diabetic retinopathy, and glaucoma. Accurate segmentation provides crucial vessel morphology details, aiding the early detection and intervention of ophthalmic diseases. However, current algorithms struggle with fine vessel segmentation and maintaining sensitivity in complex regions. Challenges also stem from imaging variability and poor generalization across multimodal datasets, highlighting the need for more advanced algorithms in clinical practice.
Methods: This paper aims to explore a new vessel segmentation method to alleviate the above problems. We propose a fundus vessel segmentation model based on a combination of double skip connections, deep supervision, and TransUNet, namely DS2TUNet. Initially, the original fundus images are improved through grayscale conversion, normalization, histogram equalization, gamma correction, and other preprocessing techniques. Subsequently, by utilizing the U-Net architecture, the preprocessed fundus images are segmented to obtain the final vessel information. Specifically, the encoder firstly incorporates the ResNetV1 downsampling, dilated convolution downsampling, and Transformer to capture both local and global features, which upgrades its vessel feature extraction ability. Then, the decoder introduces the double skip connections to facilitate upsampling and refine segmentation outcomes. Finally, the deep supervision module introduces multiple upsampling vessel features from the decoder into the loss function, so that the model can learn vessel feature representations more effectively and alleviate gradient vanishing during the training phase.
Results: Extensive experiments on publicly available multimodal fundus datasets such as DRIVE, CHASE_DB1, and ROSE-1 demonstrate that the DS2TUNet model attains F1-scores of 0.8195, 0.8362, and 0.8425, with Accuracy of 0.9664, 0.9741, and 0.9557, Sensitivity of 0.8071, 0.8101, and 0.8586, and Specificity of 0.9823, 0.9869, and 0.9713, respectively. Additionally, the model also exhibits excellent test performance on the clinical fundus dataset CSC, with F1-score of 0.7757, Accuracy of 0.9688, Sensitivity of 0.8141, and Specificity of 0.9801 based on the weight trained on the CHASE_DB1 dataset. These results comprehensively validate that the proposed method obtains good performance in fundus vessel segmentation, thereby aiding clinicians in the further diagnosis and treatment of fundus diseases in terms of effectiveness and feasibility.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11487527 | PMC |
http://dx.doi.org/10.3389/fcell.2024.1477819 | DOI Listing |
Semin Vasc Surg
September 2025
Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115; Center for Surgery and Public Health, Boston, MA; Harvard Medical School, Boston, MA. Electronic address:
The rate of end-stage kidney disease (ESKD) is steadily rising in the United States, and older adults (ie, 65 years and older) represent the fastest-growing segment in need of hemodialysis. This demographic shift presents unique challenges due to age-related comorbidities, frailty, and increased procedural risks. Despite these challenges, there is limited guidance for risk stratification and management of renal replacement therapy in older patients with ESKD.
View Article and Find Full Text PDFBiomed Phys Eng Express
September 2025
College of Computer Science and Technology, China University of Petroleum East China - Qingdao Campus, College of Computer Science and Technology, China University of Petroleum (East China), Qingdao 266580, China, Qingdao, Shandong, 266580, CHINA.
Purpose: Cerebrovascular segmentation is crucial for the diagnosis and treatment of cerebrovascular diseases. However, accurately extracting cerebral vessels from Time-of-Flight Magnetic Resonance Angiography (TOF-MRA) remains challenging due to the topological complexity and anatomical variability.
Methods: This paper presents a novel Y-shaped segmentation network with fast Fourier convolution and Mamba, termed F-Mamba-YNet.
Ultraschall Med
September 2025
Division of Prenatal Medicine, Gynecological Ultrasound and Fetal Surgery, Department of Obstetrics and Gynecology, University Hospital, Cologne, Germany.
Approximately 0.8 % of all children are born with heart defects, with the prenatal incidence naturally being even higher. Among all congenital heart defects (CHD), conotruncal anomalies are the most common critical heart defects - after ventricular and atrial septal defects.
View Article and Find Full Text PDFNeural Netw
September 2025
Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen, China. Electronic address:
Automatic segmentation of retinal vessels from retinography images is crucial for timely clinical diagnosis. However, the high cost and specialized expertise required for annotating medical images often result in limited labeled datasets, which constrains the full potential of deep learning methods. Recent advances in self-supervised pretraining using unlabeled data have shown significant benefits for downstream tasks.
View Article and Find Full Text PDFPLoS One
September 2025
School of Medical Engineering, Xinxiang Medical University, Xinxiang, China.
Computer-aided diagnostic (CAD) systems for color fundus images play a critical role in the early detection of fundus diseases, including diabetes, hypertension, and cerebrovascular disorders. Although deep learning has substantially advanced automatic segmentation techniques in this field, several challenges persist, such as limited labeled datasets, significant structural variations in blood vessels, and persistent dataset discrepancies, which continue to hinder progress. These challenges lead to inconsistent segmentation performance, particularly for small vessels and branch regions.
View Article and Find Full Text PDF