A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Microstructure, Mechanical Properties and Corrosion Performance of Laser-Welded NiTi Shape Memory Alloy in Simulated Body Fluid. | LitMetric

Microstructure, Mechanical Properties and Corrosion Performance of Laser-Welded NiTi Shape Memory Alloy in Simulated Body Fluid.

Materials (Basel)

Department of Mechanical Engineering, BK21 FOUR ERICA-ACE Center, Hanyang University, 55, Hanyangdaehak-ro, Sangnok-gu, Ansan 15588, Gyeonggi-do, Republic of Korea.

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Laser-welding is a promising technique for welding NiTi shape memory alloys with acceptable tensile strength and comparable corrosion performance for biomedical applications. The microstructural characteristics and localized corrosion behavior of NiTi alloys in a simulated body fluid (SBF) environment are evaluated. A microstructural examination indicated the presence of fine and equiaxed grains with a B2 austenite phase in the base metal (BM), while the weld metal (WM) had a coarse dendritic microstructure with intermetallic precipitates including TiNi and NiTi. The hardness decreased from the BM to the WM, and the average hardness for the BM was 352 ± 5 HV, while it ranged between 275 and 307 HV and 265 and 287 HV for the HAZ and WM, respectively. Uni-axial tensile tests revealed a substantial decrease in the tensile strength of NiTi WM (481 ± 19 MPa), with a reduced joint efficiency of 34%. The localized corrosion performance of NiTi BM was superior to the WM, with electrochemical test responses indicating a pitting potential and low corrosion rate in SBF environments. The corrosion rate of the NiTi BM and WM was 0.048 ± 0.0018 mils per year (mpy) and 0.41 ± 0.019 mpy, respectively. During welding, NiTi's strength and biocompatibility properties changed due to the alteration in microstructure and formation of intermetallic phases as a result of Ti enrichment. The performance and safety of welded medical devices may be impacted during welding, and it is essential to preserve the biocompatibility of NiTi components for biomedical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11478209PMC
http://dx.doi.org/10.3390/ma17194801DOI Listing

Publication Analysis

Top Keywords

corrosion performance
12
niti
8
niti shape
8
shape memory
8
simulated body
8
body fluid
8
tensile strength
8
biomedical applications
8
localized corrosion
8
corrosion rate
8

Similar Publications