A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design, fabrication, and calibration of a micromachined thermocouple for biological applications in temperature monitoring. | LitMetric

Design, fabrication, and calibration of a micromachined thermocouple for biological applications in temperature monitoring.

Biosens Bioelectron

The Estelle and Daniel Maggin Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA; BioMedical Engineering & Imaging Institute, Leon and Norma Hess Center for Science and Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, 10029, USA. Electronic add

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This paper presents a microneedle thermocouple probe designed for temperature measurements in biological samples, addressing a critical need in the field of biology. Fabricated on a Silicon-On-Insulator (SOI) wafer, the probe features a doped silicon (Si)/chrome (Cr)/gold (Au) junction, providing a high Seebeck coefficient, rapid response times, and excellent temperature resolution. The microfabrication process produces a microneedle with a triangular sensing junction. Finite Element Analysis (FEA) was employed to evaluate the thermal time constant and structural integrity in tissue, supporting the probe's suitability for biological applications. Experimental validation included temperature measurements in ex-vivo tissue and live Xenopus laevis oocytes. Notably, intracellular thermogenesis was detected by increasing extracellular potassium concentration to depolarize the oocyte membrane, resulting in a measurable temperature rise. These findings highlight the probe's potential as a robust tool for monitoring temperature variations in biological systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2024.116835DOI Listing

Publication Analysis

Top Keywords

biological applications
8
temperature measurements
8
temperature
6
design fabrication
4
fabrication calibration
4
calibration micromachined
4
micromachined thermocouple
4
biological
4
thermocouple biological
4
applications temperature
4

Similar Publications