A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Investigation of Type A Aortic Dissection Using Computational Modelling. | LitMetric

Investigation of Type A Aortic Dissection Using Computational Modelling.

Biomedicines

Department of Vascular & Endovascular Surgery, Waikato Hospital, Hamilton 3204, New Zealand.

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aortic dissection is a catastrophic failure of the endothelial wall that could lead to malperfusion or rupture. Computational modelling tools may help detect arterial damage. Technological advancements have led to more sophisticated forms of modelling being made available to low-grade computers. These devices can create 3D models with clinical data, where the clinical blood pressure waveforms' model can be used to form boundary conditions for assessing hemodynamic parameters, modelling blood flow propagation along the aorta to predict the development of cardiovascular disease. This study presents patient-specific data for a rare case of severe Type A aortic dissection. CT scan images were taken nine months apart, consisting of the artery both before and after dissection. The results for the pre-dissection CT showed that the pressure waveform at the ascending aorta was higher, and the systolic pressure was lagging at the descending aorta. For the post-dissection analysis, we observed the same outcome; however, the amplitude for the waveform (systolic pressure) at the ascending aorta increased in the false lumen by 25% compared to the true lumen by 3%. Also, the waveform peak (systolic) was leading by 0.01 s. The hemodynamic parameter of wall shear stress (WSS) predicted the aneurysm's existence at the ascending aorta, as well as potential aortic dissection. The high WSS contours were located at the tear location at the peak blood flow of 0.14 s, which shows the potential of this tool for earlier diagnosis of aortic dissection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11428704PMC
http://dx.doi.org/10.3390/biomedicines12091973DOI Listing

Publication Analysis

Top Keywords

aortic dissection
20
ascending aorta
12
type aortic
8
computational modelling
8
blood flow
8
systolic pressure
8
dissection
6
aortic
5
aorta
5
investigation type
4

Similar Publications