A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Performance of point-of-care glucose testing for the diagnosis of gestational diabetes in South Africa. | LitMetric

Performance of point-of-care glucose testing for the diagnosis of gestational diabetes in South Africa.

Int J Gynaecol Obstet

Wits Diagnostic and Innovation Hub, National Health Laboratory Service, Johannesburg, South Africa.

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Lack of accessibility to oral glucose tolerance tests (OGTTs) in South Africa means many pregnant women go without testing for gestational diabetes mellitus (GDM). This study evaluated point-of-care (POC) glucometers against the laboratory-based glucose method in pregnant women.

Methods: This was a cross-sectional study on pregnant women attending the prenatal clinic in Johannesburg who were recommended for the OGTT. OGTTs were conducted as per International Association of Diabetes and Pregnancy Study Groups (IADPSG) guidelines. Women who consented to the study donated both venous and capillary blood for laboratory-based and POC glucose measurements using seven POC glucometers: I-STAT, Xpress, LDX, VivaChek-Ino, Accu-Chek Active, StatStrip, and Codefree. By assessing sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) and comparing Bland-Altman plots, the diagnostic accuracy of each glucose meter was compared with the reference method, the laboratory-based glucose method.

Results: Data were analyzed for 1076 pregnant women. Based on OGTT testing, 83 women had GDM (7.7%). Overall, the POC glucometers performed poorly, with sensitivity ranging from 17.6% to 87.18% and specificity ranging between 62.7% and 99.8%. The AUC ranged from 0.59 to 0.79. All POC glucometers showed moderate to poor reliability. Laboratory-based fasting plasma glucose (FPG) surpassed the POC glucometers in sensitivity, specificity, and AUC, with values of 94.0%, 100%, and 0.98, respectively.

Conclusion: We demonstrated that laboratory-based FPG has the potential to be used as a diagnostic test for GDM and that the POC glucometers cannot replace OGTT laboratory-based measurements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11726129PMC
http://dx.doi.org/10.1002/ijgo.15914DOI Listing

Publication Analysis

Top Keywords

poc glucometers
24
pregnant women
12
gestational diabetes
8
south africa
8
laboratory-based glucose
8
sensitivity specificity
8
glucose
7
poc
7
glucometers
6
laboratory-based
6

Similar Publications