98%
921
2 minutes
20
This study investigates the determination of the centre of pressure (COP) on spherical sports objects such as cricket balls and footballs using gyroscope data from Inertial Measurement Units (IMUs). Conventional pressure sensors are not suitable for capturing the tangential forces responsible for torque generation. This research presents a novel method to calculate the COP solely from gyroscope data and avoids the complexity of isolating user-induced accelerations from IMU data. The COP is determined from the cross-product of consecutive torque vectors intersecting the surface of the sphere. Effective noise management techniques, including filtering and data interpolation, were employed to improve COP visualisation. Experiments were conducted using a smart cricket ball and a smart football. Validation tests using spin rates between 7.5 and 12 rps and torques ranging from 0.08 to 0.12 Nm confirmed consistent COP clustering around the expected positions. Further analysis extended to various spin bowling deliveries recorded using a smart cricket ball, and a curved football kick recorded using a smart football demonstrated the wide applicability of the method. The COPs of various spin bowling deliveries showed adjacent positions on the surface of the ball, traversing through backspin, sidespin and topspin, excluding the flipper and doosra deliveries. The calculation of the COP on the surface of the soccer ball could only be achieved by increasing the data sampling frequency sevenfold using curve fitting. Knowledge and use of the COP position offers significant advances in understanding and analysing ball dynamics in sports.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11398119 | PMC |
http://dx.doi.org/10.3390/s24175810 | DOI Listing |
J Med Internet Res
September 2025
Centre Hospitalier Rives de Seine, Courbevoie, France.
Background: Every year in France, 40% of people aged ≥80 years are hospitalized, with an average length of hospital stay of 25 days and a readmission rate of 14% to 30% within the month following discharge. This situation is putting pressure on the health care system, encouraging the reinforcement of home care to reduce avoidable hospitalization. The EPOCA remote patient monitoring (RPM) system is a medical and social telehealth solution specialized in RPM, teleconsultation, tele-expertise, and care coordination in emergency medicine and geriatrics.
View Article and Find Full Text PDFJ Med Internet Res
September 2025
Faculty of Medicine, The University of Sydney, Sydney, Australia.
Background: Hypertensive disorders of pregnancy (HDP) affect up to 10% of pregnancies and can have adverse short and long-term implications for women and their babies. eHealth interventions include any health service or treatment delivered using the internet and related technology that aims to facilitate, capture, or exchange knowledge. eHealth interventions are increasingly used across many health care settings with improved outcomes.
View Article and Find Full Text PDFAnn Am Thorac Soc
September 2025
University of Florida, Department of Medicine, Gainesville, Florida, United States;
Background: Pulmonary hypertension (PH) is a systemic illness with increasingly subtle disease manifestations including sleep disruption. Patients with PH are at increased risk for disturbances in circadian biology, although to date there is no data on "morningness" or "eveningness" in pulmonary vascular disease.
Research Questions: Our group studied circadian rhythms in PH patients based upon chronotype analysis, to explore whether there is a link between circadian parameters and physiologic risk-stratifying factors to inform novel treatment strategies in patients with PH?
Study Design And Methods: We serially recruited participants from July 2022 to March 2024, administering in clinic the Munich Chronotype Questionnaire (MCTQ).
J Appl Physiol (1985)
September 2025
Women's Heart Health Laboratory, Institute for Exercise and Environmental Medicine at Texas Health Presbyterian Hospital Dallas, TX, USA.
We investigated the impact of short-term dietary nitrate supplementation on sympathetic neural responses to isometric exercise in postmenopausal women. Ten healthy women aged 64±2 (SD) years participated in this randomized, placebo-controlled, double-blind, crossover study. All participants underwent two-week beetroot juice (BRJ: 800 mg nitrate/day) and placebo (nitrate-depleted BRJ) interventions with ≥14 days of wash-out.
View Article and Find Full Text PDFSci Adv
September 2025
State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En
Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.
View Article and Find Full Text PDF