98%
921
2 minutes
20
Introduction: This study aimed to rank definitions for measuring poor response one year after TKA, after assessing the face validity and feasibility of existing or newly proposed definitions.
Materials And Methods: An international, three-round, online modified Delphi study was conducted with sixty-nine panelists from twenty-three countries. Definitions were derived from a literature review or were newly proposed by an expert group. Panelists rated the face validity and feasibility of definitions, and could propose additional new definitions in round 1. Panelists reconsidered their rating of existing definitions, and rated newly suggested definitions (round 2). Definitions with a median score for face validity < 6.5 were removed from the list, and panelists distributed 100 points among the remaining definitions for ranking (round 3).
Results: Fifty-one panelists completed all three rounds (response rate 74%), and the prioritized list of definitions in round 3 comprised seventeen definitions. The single-item definition of (dis)satisfaction with the outcome of TKA obtained the highest scores for face validity and feasibility (7.5, and 8.5 respectively), and the definition "No improvement in pain OR daily knee functioning compared to pre-operative status" was the highest prioritized. In general, definitions reflecting change from the perception of patients were higher ranked than definitions requiring both preoperative and postoperative assessment of validated questionnaires.
Conclusions: This study identified seventeen potential definitions of poor response to TKA, offering valuable options for integration into quality assessment investigations. Remarkably, all identified definitions were patient-centered and none were clinician-centered. Single-item questions, capturing change from the patient's viewpoint, appear to be the most practicable format to assess response.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11582167 | PMC |
http://dx.doi.org/10.1007/s00402-024-05515-y | DOI Listing |
Multimed Man Cardiothorac Surg
September 2025
Department of Thoracic Surgery, New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton, UK
Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as the pioneering approach for the most complex of pulmonary resections, offering high-definition 3D visualization, enhanced instrument augmentation and tremor-free tissue articulation. Compared with open thoracotomy, the robotic platform is associated with reduced peri-operative morbidity, shorter hospital admissions and faster patient recovery. However, sublobar resections such as segmentectomies remain anatomically and technically demanding, particularly in the context of resecting multiple segments, as showcased in this right S1 and S2 segmentectomy.
View Article and Find Full Text PDFMultimed Man Cardiothorac Surg
September 2025
Department of Cardiothoracic Surgery, St George’s Hospital, St George's University Hospitals NHS Foundation Trust, London, UK
Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as a leading technique for undertaking the most complex pulmonary resections, providing high-definition 3D visualization, advanced instrument control and tremor-free tissue handling. Compared with open thoracotomy, the robotic platform offers reduced peri-operative complications, shorter hospital stays and faster patient recovery. Nevertheless, sublobar resections, such as segmentectomies, remain both anatomically intricate and technically challenging, particularly when resecting multiple segments, as in this left S1 and S2 segmentectomy.
View Article and Find Full Text PDFJ Prosthodont
September 2025
Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
Purpose: This study aimed to evaluate the inherent and after cyclic loading fracture strength of implant-supported cantilevered fixed prostheses fabricated from recently introduced additively manufactured (AM) and subtractively manufactured (SM) materials, considering variations in prosthesis height.
Materials And Methods: Three cylinder-shaped master files (20 mm long and 11 mm wide) with varying heights (7, 11, and 15 mm) and a titanium-base (Ti-base) abutment space were designed. These designs were used to fabricate a total of 144 specimens with two AM resins indicated for definitive use (Crowntec; AM-CT and Flexcera Smile Ultra+; AM-FS), one high-impact polymer composite (breCAM.
Appl Environ Microbiol
September 2025
Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
Unlabelled: The genus includes opportunistic pathogens inhabiting engineered aquatic ecosystems, where managing their presence and abundance is crucial for public health. In these environments, interact positively or negatively with multiple members of the microbial communities. Here, we identified bacteria and compounds with -antagonistic properties.
View Article and Find Full Text PDF