A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Feasibility of simulation free abdominal stereotactic adaptive radiotherapy using an expedited pre-plan workflow. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Purpose: Improved hounsfield-unit accuracy of on-board imaging may lead to direct-to-unit treatment approaches We aimed to demonstrate the feasibility of using only a diagnostic (dx) computed tomography (CT)-defined target pre-plan in an study of simulation-free abdominal stereotactic adaptive radiotherapy (ART).

Materials And Methods: Eight patients with abdominal treatment sites (five pancreatic cancer, three oligometastases) were treated using an integrated adaptive O-Ring gantry system. Each patient's target was delineated on a dxCT. The target only pre-plan served primarily to seed the ART process. During the ART session, all structures were delineated. All simulated cases were treated to 50 Gy in 5 fractions to a planning target optimization structure (PTV_OPT) to allow for dose escalation within the planning target volume. Timing of steps during this workflow was recorded. Plan quality was compared between ART treatment plans and a plan created on a CT simulation scan using the traditional planning workflow.

Results: The workflow was feasible in all attempts, with organ-at-risk (OAR) constraints met in all fractions despite lack of initial OAR contours. Median absolute difference between the adapted plan and simulation CT plan for the PTV_Opt V95% was 2.0 %. Median absolute difference in the D0.5 cm between the adapted plan and simulation CT plan was -0.9 Gy for stomach, 1.2 Gy for duodenum, -5.3 Gy for small bowel, and 0.3 Gy for large bowel. Median end-to-end workflow time was 63 min.

Conclusion: The workflow was feasible for a dxCT-defined target-only pre-plan approach to stereotactic abdominal ART.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11382001PMC
http://dx.doi.org/10.1016/j.phro.2024.100611DOI Listing

Publication Analysis

Top Keywords

abdominal stereotactic
8
stereotactic adaptive
8
adaptive radiotherapy
8
target pre-plan
8
planning target
8
workflow feasible
8
median absolute
8
absolute difference
8
adapted plan
8
plan simulation
8

Similar Publications