A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The Romanian translation and validation of the Extended Prostate Cancer Index Composite in patients undergoing radical prostatectomy. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: To evaluate the quality of life in patients treated for prostate cancer in detail, an accessible, extensive, and easy-to-administer questionnaire is needed. The self-administered 50-item "Expanded Prostate Cancer Index Composite" (EPIC) is an instrument used for this purpose, but it is not officially translated into Romanian. The aim of the study was to translate and validate the Romanian version of the EPIC.

Methods: We translated and culturally adapted the EPIC into Romanian. For validation, we included a retrospective analysis of 112 patients who underwent robotic radical prostatectomy and a prospective study including 120 consecutive patients hospitalized before surgical treatment. Baseline and follow-up assessments took place before and at six months, two, and five years post-surgery, between January 2014 and December 2015. We performed cross-sectional correlations between the EPIC, AUASI, and SF-12 at baseline, factor analysis, and calculated the internal consistency.

Results: For most EPIC domains and subscales, our a priori-defined criteria for reliability were fulfilled (Cronbach's alpha 0.7-0.9). Cross-sectional correlations between EPIC scales and AUASI domain ranged from 0.23-0.69, and SF-12 domains ranged from 0.21-0.53 and 0.22-0.61, respectively. The retrospective analysis showed a medium acceptability and understanding of the EPIC questionnaire. In the prospective study, the revised EPIC draft showed an overall higher acceptability with a responding rate of 66% at a 5-year follow-up. All domains exhibited good internal consistency except for the hormonal section (Cronbach's α = 0.67) at the 6-month follow-up.

Conclusion: The Romanian version of the EPIC is reliable, responsive and valid for measuring HRQL in prostate cancer patients. The EPIC questionnaire proved to be an exhaustive and reproducible instrument for evaluating the quality of life in Romanian prostate cancer patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11370850PMC
http://dx.doi.org/10.15386/mpr-2757DOI Listing

Publication Analysis

Top Keywords

prostate cancer
20
epic
9
radical prostatectomy
8
quality life
8
romanian version
8
retrospective analysis
8
prospective study
8
cross-sectional correlations
8
correlations epic
8
epic questionnaire
8

Similar Publications