A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessment of Hip and Lumbar Spine Range of Motion After Total Hip Arthroplasty Using a Single Camera Markerless System. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Total hip arthroplasty (THA) is one of the most cost-effective and successful procedures in orthopedics. However, assessing the post-operative range of motion (ROM) remains a challenge due to the limitations of traditional measurement methods. This study aimed to evaluate hip and spine ROM post-operatively and single-leg balance, using a single-camera markerless motion capture system, and compare outcomes with pre-operative ROM and with an age-matched healthy control group.

Methods: An interventional study was conducted from January 2018 to December 2021. Twenty patients with hip osteoarthritis underwent THA and were assessed using a single-camera markerless system (Kinetisense software). Measurements were taken one month pre-operatively and one year post-operatively.

Results: Significant improvements were observed in hip and lumbar spine ROM variables after THA. The most notable enhancements were in hip and spinal flexion. Compared to the control group, the THA group showed minor deficits in hip ROM, particularly in external rotation. Single-leg balance demonstrated improved stability post-operatively.

Conclusions: The single-camera markerless motion capture system offers a promising alternative for assessing hip and lumbar spine ROM, presenting potential advantages over manual goniometry and traditional 3D motion capture systems. Using this system for the evaluation of patients after THA, it seems that THA significantly enhances hip and lumbar spine ROM. Future research should focus on validating the accuracy of markerless systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11364358PMC
http://dx.doi.org/10.7759/cureus.65875DOI Listing

Publication Analysis

Top Keywords

hip lumbar
16
lumbar spine
16
single-camera markerless
12
motion capture
12
spine rom
12
hip
9
range motion
8
total hip
8
hip arthroplasty
8
markerless system
8

Similar Publications