Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Total hip arthroplasty (THA) is one of the most cost-effective and successful procedures in orthopedics. However, assessing the post-operative range of motion (ROM) remains a challenge due to the limitations of traditional measurement methods. This study aimed to evaluate hip and spine ROM post-operatively and single-leg balance, using a single-camera markerless motion capture system, and compare outcomes with pre-operative ROM and with an age-matched healthy control group.
Methods: An interventional study was conducted from January 2018 to December 2021. Twenty patients with hip osteoarthritis underwent THA and were assessed using a single-camera markerless system (Kinetisense software). Measurements were taken one month pre-operatively and one year post-operatively.
Results: Significant improvements were observed in hip and lumbar spine ROM variables after THA. The most notable enhancements were in hip and spinal flexion. Compared to the control group, the THA group showed minor deficits in hip ROM, particularly in external rotation. Single-leg balance demonstrated improved stability post-operatively.
Conclusions: The single-camera markerless motion capture system offers a promising alternative for assessing hip and lumbar spine ROM, presenting potential advantages over manual goniometry and traditional 3D motion capture systems. Using this system for the evaluation of patients after THA, it seems that THA significantly enhances hip and lumbar spine ROM. Future research should focus on validating the accuracy of markerless systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11364358 | PMC |
http://dx.doi.org/10.7759/cureus.65875 | DOI Listing |