A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessing aortic motion with automated 3D cine balanced steady state free precession cardiovascular magnetic resonance segmentation. | LitMetric

Assessing aortic motion with automated 3D cine balanced steady state free precession cardiovascular magnetic resonance segmentation.

J Cardiovasc Magn Reson

Amsterdam UMC location University of Amsterdam, Radiology and Nuclear Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Cardiovascular Sciences, Atherosclerosis and Ischemic Syndromes, Amsterdam, the Netherlands. Electronic address:

Published: December 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To apply a free-running three-dimensional (3D) cine balanced steady state free precession (bSSFP) cardiovascular magnetic resonance (CMR) framework in combination with artificial intelligence (AI) segmentations to quantify time-resolved aortic displacement, diameter and diameter change.

Methods: In this prospective study, we implemented a free-running 3D cine bSSFP sequence with scan time of approximately 4 min facilitated by pseudo-spiral Cartesian undersampling and compressed-sensing reconstruction. Automated segmentation of the aorta in all cardiac timeframes was applied through the use of nnU-Net. Dynamic 3D motion maps were created for three repeated scans per volunteer, leading to the detailed quantification of aortic motion, as well as the measurement and change in diameter of the ascending aorta.

Results: A total of 14 adult healthy volunteers (median age, 28 years (interquartile range [IQR]: 26.0-31.3), 6 females) were included. Automated segmentation compared to manual segmentation of the aorta test set showed a Dice score of 0.93 ± 0.02. The median (IQR) over all volunteers for the largest maximum and mean ascending aorta (AAo) displacement in the first scan was 13.0 (4.4) mm and 5.6 (2.4) mm, respectively. Peak mean diameter in the AAo was 25.9 (2.2) mm and peak mean diameter change was 1.4 (0.5) mm. The maximum individual variability over the three repeated scans of maximum and mean AAo displacement was 3.9 (1.6) mm and 2.2 (0.8) mm, respectively. The maximum individual variability of mean diameter and diameter change were 1.2 (0.5) mm and 0.9 (0.4) mm.

Conclusion: A free-running 3D cine bSSFP CMR scan with a scan time of four minutes combined with an automated nnU-net segmentation consistently captured the aorta's cardiac motion-related 4D displacement, diameter, and diameter change.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11615597PMC
http://dx.doi.org/10.1016/j.jocmr.2024.101089DOI Listing

Publication Analysis

Top Keywords

diameter diameter
12
diameter change
12
diameter
9
aortic motion
8
cine balanced
8
balanced steady
8
steady state
8
state free
8
free precession
8
cardiovascular magnetic
8

Similar Publications