Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Recurrences due to discontinuity in ablation lines are substantial after pulmonary vein isolation (PVI) with radiofrequency ablation for atrial fibrillation. Data are scarce regarding the durability predictors for very high-power short-duration (vHPSD, 90 W/4 s) ablation.

Methods: A total of 20 patients were enrolled, who underwent 90 W PVI and a mandatory remapping procedure at 3 months. First-pass isolation (FPI) gaps, and acute pulmonary vein reconnection (PVR) sites were identified at the index procedure; and chronic PVR sites were identified at the repeated procedure. We analyzed parameters of ablation points (n = 1357), and evaluated their roles in predicting a composite endpoint of FPI gaps, acute and chronic PVR.

Results: In total, 45 initial ablation points corresponding to gaps in the ablation lines were analyzed. Parameters associated with gaps were interlesion distance (ILD), baseline generator impedance, mean current, total charge, and loss of catheter-tissue contact. The optimal ILD cut-off for predicting gaps was 3.5 mm anteriorly, and 4 mm posteriorly.

Conclusions: Biophysical characteristics dependent on generator impedance could affect the efficacy of vHPSD PVI. The use of smaller ILDs is required for effective and durable PVI with vHPSD compared to the consensus targets with lower power ablation, and lower ILDs for anterior applications seem necessary compared to posterior points.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11354231PMC
http://dx.doi.org/10.3390/jcdd11080230DOI Listing

Publication Analysis

Top Keywords

pulmonary vein
16
vein reconnection
8
high-power short-duration
8
vein isolation
8
ablation lines
8
fpi gaps
8
gaps acute
8
pvr sites
8
sites identified
8
analyzed parameters
8

Similar Publications

Background: Balancing the risks of thrombotic and bleeding events in people with advanced kidney disease is a clinical challenge.

Objectives: To estimate rates of major adverse thrombotic events (MATEs) and bleeding events in individuals with chronic kidney disease (CKD) stages 4 or 5 or with end-stage kidney disease (ESKD) receiving hemodialysis (HD) or peritoneal dialysis (PD).

Methods: Using administrative claims from a 20% Medicare sample, Optum's de-identified Clinformatics Data Mart Database, and the US Renal Data System from 2016-2019, we identified individuals with CKD stages 4 or 5 and individuals with dialysis-dependent ESKD.

View Article and Find Full Text PDF

Background: Catheter ablation is beneficial in patients with symptomatic persistent atrial fibrillation (PerAF), and pulsed field ablation (PFA) is a promising energy source to safely and durably create ablation lesions. However, catheter-specific "PFA waveforms and designs" result in effectiveness and safety profiles that are not transferable to other PFA technologies. A head-to-head comparison between the dual-energy, wide-footprint lattice-tip (Sphere-9, Medtronic) and pentaspline PFA catheter (Farawave, Boston Scientific) is not yet available.

View Article and Find Full Text PDF

Introduction: Pulmonary embolism (PE) is a life-threatening condition with well-defined management strategies; however, the presence of a clot-in-transit (CIT)-a mobile thrombus within the right heart-introduces a uniquely high-risk scenario associated with a significantly elevated mortality rate. While several therapeutic approaches are available-including anticoagulation, systemic thrombolysis, surgical embolectomy, and catheter-directed therapies-there is no established consensus on a superior treatment modality. Catheter-based mechanical thrombectomy has emerged as a promising, minimally invasive alternative that mitigates the bleeding risks of systemic thrombolysis and the invasiveness of surgery.

View Article and Find Full Text PDF

Tuberculosis (TB) is a multisystem infectious disease with both pulmonary and extrapulmonary manifestations. TB can also induce a hypercoagulable state, setting off a cascade of changes in the body, including systemic inflammation, endothelial dysfunction, and abnormalities in the coagulation and fibrinolytic pathways. Collectively, these factors significantly increase the risk of venous thromboembolism, such as deep vein thrombosis and pulmonary embolism.

View Article and Find Full Text PDF

We present a rare anatomical variation of the deep femoral vein (DFV) originating from the popliteal vein (PV) with an associated aneurysm. The DFV arose from the PV at the adductor hiatus, exhibited an aneurysm, and coursed upward through the fourth osseo-aponeurotic opening of the adductor magnus muscle to enter the anterior thigh compartment before draining into the femoral vein. This unique variation likely resulted from developmental deviations during intrauterine life.

View Article and Find Full Text PDF