A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Characterizing Cochlear Implant Trans-Impedance Matrix Heatmaps in Patients With Abnormal Anatomy. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To characterize transimpedance matrix (TIM) heatmap patterns in patients at risk of labyrinthine abnormality to better understand accuracy and possible TIM limitations.

Study Design: Retrospective review of TIM patterns, preoperative, and postoperative imaging.

Setting: Tertiary referral center.

Patients: Patients undergoing cochlear implantation with risk of labyrinthine abnormality.

Intervention: None.

Results: Seventy-seven patients were evaluated. Twenty-five percent (n = 19) of patients had a TIM pattern variant identified. These variants were separated into 10 novel categories. Overall, 9% (n = 6) of electrodes were malpositioned on intraoperative x-ray, of which 50% (n = 3) were underinserted, 17% (n = 1) were overinserted, 17% (n = 1) had a tip foldover, and 17% (n = 1) had a coiled electrode. The number of patients with a variant TIM pattern and normal x-ray was 18% (n = 14), and the number of patients with normal TIM pattern and malposition noted on x-ray was 3% (n = 2; both were electrode underinsertions that were recognized due to open circuits and surgical visualization).A newly defined skip heat pattern was identified in patients with IP2/Mondini malformation and interscalar septum width <0.5 mm at the cochlear pars ascendens of the basal turn.

Conclusions: This study defines novel patterns for TIM heatmap characterization to facilitate collaborative and comparative research moving forward. In doing so, it highlights a new pattern termed skip heat, which corresponds with a deficient interscalar septum of the cochlea pars ascendens of the basal turn in patients with IP2 malformation. Overall, the data assist the surgeon in better understanding the implications and limitations of TIM patterns within groups of patients with risk of labyrinthine abnormalities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12204388PMC
http://dx.doi.org/10.1097/MAO.0000000000004304DOI Listing

Publication Analysis

Top Keywords

tim pattern
12
patients
8
risk labyrinthine
8
number patients
8
tim
6
characterizing cochlear
4
cochlear implant
4
implant trans-impedance
4
trans-impedance matrix
4
matrix heatmaps
4

Similar Publications