A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An ultrasound multiparametric method to quantify liver fat using magnetic resonance as standard reference. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background & Aims: There is an unmet need for a reliable and reproducible non-invasive measure of fatty liver content (FLC) for monitoring steatotic liver disease in clinical practice. Sonographic FLC assessment is qualitative and operator-dependent, and the dynamic quantification range of algorithms based on a single ultrasound (US) parameter is unsatisfactory. This study aims to develop and validate a new multiparametric algorithm based on B-mode images to quantify FLC using Magnetic Resonance (MR) values as standard reference.

Methods: Patients with elevated liver enzymes and/or bright liver at US (N = 195) underwent FLC evaluation by MR and by US. Five US-derived quantitative features [attenuation rate(AR), hepatic renal-ratio(HR), diaphragm visualization(DV), hepatic-portal-vein-ratio(HPV), portal-vein-wall(PVW)] were combined by mixed linear/exponential regression in a multiparametric model (Steatoscore2.0). One hundred and thirty-four subjects were used for training and 61 for independent validations; score-computation underwent an inter-operator reproducibility analysis.

Results: The model is based on a mixed linear/exponential combination of 3 US parameters (AR, HR, DV), modelled by 2 equations according to AR values. The computation of FLC by Steatoscore2.0 (mean ± std, 7.91% ± 8.69) and MR (mean ± std, 8.10% ± 10.31) is highly correlated with a low root mean square error in both training/validation cohorts, respectively (R = 0.92/0.86 and RMSE = 5.15/4.62, p < .001). Steatoscore2.0 identified patients with MR-FLC≥5%/≥10% with sensitivity = 93.2%/89.4%, specificity = 86.1%/95.8%, AUROC = 0.958/0.975, respectively and correlated with MR (R = 0.92) significantly (p < .001) better than CAP (R = 0.73).

Conclusions: Multiparametric Steatoscore2.0 measures FLC providing values highly comparable with MR. It is reliable, inexpensive, easy to use with any US equipment and qualifies to be tested in larger, prospective studies as new tool for the non-invasive screening and monitoring of FLC.

Download full-text PDF

Source
http://dx.doi.org/10.1111/liv.16078DOI Listing

Publication Analysis

Top Keywords

magnetic resonance
8
mixed linear/exponential
8
liver
5
flc
5
ultrasound multiparametric
4
multiparametric method
4
method quantify
4
quantify liver
4
liver fat
4
fat magnetic
4

Similar Publications