A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Validating an Evoked Potential Platform for Electrocochleography During Cochlear Implantation. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To validate electrocochleography (ECochG) between an auditory evoked potential (AEP) machine and an established cochlear implant (CI) manufacturer ECochG system.

Methods: Intraoperative validation study at a tertiary referral center. Patients included adults and children undergoing cochlear implantation. Intraoperative ECochG was measured with both the Intelligent Hearing Systems (IHS) Duet AEP machine and Cochlear Corporation (CC) ECochG platform. Recording electrodes captured extracochlear measurements through a standard facial recess. Tone-bursts were presented from 250 Hz to 2 kHz (~110 dB SPL). A fast Fourier transform (FFT) of ECochG waveforms at key frequencies was summed into a total response (ECochG-TR). Pearson's correlation was utilized to evaluate the relationship between IHS-ECochG-TR and CC-ECochG-TR after confirming normality.

Results: Thirty patients were enrolled with an average age of 67 years (SD 18.8). In the ear that was implanted, mean preoperative pure-tone average (PTA; 0.5, 1, 2, and 4 kHz) was 87.4 dB HL (SD 19.3) and mean preoperative word-recognition scores (WRS) was 17.0% correct (SD 19.1). There was strong correlation (r = 0.905, 95% confidence interval: 0.809 to 0.954) between IHS-ECochG-TR (median 2.30 μV, range 0.1-148.26) and CC-ECochG-TR (median 3.00 μV, range 0.1-239.63). Four patients underwent transtympanic ECochG with the IHS system for feasibility evaluation and achieved similar responses.

Conclusion: Extracochlear ECochG has been predictive of CI speech perception performance. The IHS duet system is a valid measure of extracochlear ECochG for the CI population. Future work will utilize this system for measuring transtympanic ECochG to improve preoperative estimation of CI performance.

Level Of Evidence: 3 Laryngoscope, 135:308-315, 2025.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11637975PMC
http://dx.doi.org/10.1002/lary.31724DOI Listing

Publication Analysis

Top Keywords

ecochg
9
evoked potential
8
cochlear implantation
8
aep machine
8
ihs duet
8
transtympanic ecochg
8
extracochlear ecochg
8
validating evoked
4
potential platform
4
platform electrocochleography
4