A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Image-based Force Localization and Estimation of a Micro-scale Continuum Guidewire Robot. | LitMetric

Image-based Force Localization and Estimation of a Micro-scale Continuum Guidewire Robot.

IEEE Trans Med Robot Bionics

Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA.

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Many intravascular procedures are prefaced by the placement of a slender wire called a guidewire. Steering these guidewires is met with challenges in controlling the distal end along with the possibility of damaging vessel walls, or even perforation, which can be fatal. To this end, utilizing robotic guidewires can improve steerability and enable force feedback through intrinsic force sensing. Enabling force sensing contains challenges such as discrete sensor placements in continuous structures and non-unique force distributions for a given deflection. In this work, we utilize image feedback and a Cosserat rod model to estimate and localize forces along the body of a micro-scale tendon-driven guidewire robot. This includes additional modeling of friction and hysteresis that is often neglected for force sensing. The model is tested on a variety of notched nitinol tubes under gravity loading with the shape predictions having an average RMSE of 0.46 mm. Utilization of friction and hysteresis models provide shape predictions with an RMSE of 1.22 mm compared to an uncompensated model (RMSE = 1.62 mm) for approximately 180° bends. The methods presented are able to localize forces with an average error of 4.79 mm (5.15% of the length) while force magnitudes are estimated with an average error of 13.03 mN.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11342038PMC
http://dx.doi.org/10.1109/tmrb.2024.3349598DOI Listing

Publication Analysis

Top Keywords

force sensing
12
guidewire robot
8
localize forces
8
friction hysteresis
8
shape predictions
8
average error
8
force
6
image-based force
4
force localization
4
localization estimation
4

Similar Publications