98%
921
2 minutes
20
Air pollution exposure during pregnancy may affect fetal growth. Fetal growth restriction (FGR) is associated with reduced lung function in children that can persist into adulthood. Using an established model of asymmetrical FGR in Long-Evans rats, this study investigated sex differences in effects of early life ozone exposure on lung development and maturation. Adverse health effects for i) gestational exposure (with impacts on primary alveolarization), ii) peri-adolescent exposure (with impacts on secondary alveolarization), and iii) cumulative exposure across both periods were evaluated. Notably, female offspring were most affected by gestational ozone exposure, likely because of impaired angiogenesis and corresponding decreases in primary alveolarization. Females had diminished lung capacity, fewer mature alveoli, and medial hypertrophy of small and large pulmonary arteries. Males, especially FGR-prone offspring, were more affected by peri-adolescent ozone exposure. Males had increased ductal areas, likely due to disrupted secondary alveolarization. Altered lung development may increase risk of developing diseases, such as pulmonary arterial hypertension or chronic obstructive pulmonary disease. Pulmonary arterial hypertension disproportionately affects women. In the United States, chronic obstructive pulmonary disease prevalence is increasing, especially in women; and prevalence for both men and women is highest in urbanized areas. This investigation underlines the importance of evaluating results separately by sex, and provides biologic plausibility for later consequences of early-life exposure to ozone, a ubiquitous urban air pollutant.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12036003 | PMC |
http://dx.doi.org/10.1016/j.ajpath.2024.05.013 | DOI Listing |
J Occup Environ Hyg
September 2025
Division of Biology, Chemistry, and Materials Science, Office of Science and Engineering Laboratories, US Food and Drug Administration (FDA), Oak Ridge, Tennessee.
This work assesses the current characterization framework of single-use personal protective equipment (PPE) per recognized consensus standards and presents a novel quantitative approach to refining characterization of barrier materials and predicting PPE performance. Scanning electron microscopy (SEM) and image analysis software (Diameter J) were used to examine the microscopic fiber and pore structure of filter layers of surgical N95 filtering facepiece respirators, before and after exposure to chemicals used in decontamination modalities (vaporized hydrogen peroxide or ozone). The effect of porosity on penetration was assessed by bacterial filtration efficiency (BFE) testing.
View Article and Find Full Text PDFBiosaf Health
August 2025
Department of Microbiology and Immunology, University of Nevada, Reno School of Medicine, MS320, Reno 89557 Nevada, United States of America.
The role of personal protective equipment (PPE) in protecting against exposure to infectious agents and toxic chemicals is well-established. However, the global surge in PPE demand during the pandemic exposed challenges, including shortages and environmental impacts from disposable waste. Developing effective, scalable, and sustainable decontamination methods for the reuse of PPE is essential.
View Article and Find Full Text PDFEnviron Int
August 2025
Eawag: Swiss Federal Institute of Aquatic Science and Technology, Ueberlandstrasse 133, 8600, Duebendorf, Switzerland; Institute of Biogeochemistry and Pollutant Dynamics, Universitaetstrasse 16, 8092, Zurich, Switzerland. Electronic address:
Synthetic antioxidants (SAOs) are widely used additives in industrial and consumer products, yet their human exposure and fate throughout wastewater treatment remain poorly understood. This study investigates the occurrence of SAOs and their human metabolites in wastewater influent as well as their abatement in three wastewater treatment plants (WWTPs) employing both conventional and advanced treatment technologies. In vitro human liver S9 assays were performed to generate a SAO metabolite MS2 library containing over 2500 potential metabolites, which was matched against wastewater influent data.
View Article and Find Full Text PDFPharmacol Ther
September 2025
Department of Molecular Pharmacology, University of Groningen, Groningen, the Netherlands; Groningen Research Institute for Asthma and COPD, GRIAC, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands. Electronic address:
Air pollution is a significant public health issue that impacts lung health, particularly in vulnerable populations such as children, the elderly, and individuals with pre-existing respiratory conditions. Both natural and anthropogenic sources of air pollution give rise to a variety of toxic compounds, including particulate matter (PM), ozone (O₃), sulfur dioxide (SO₂), nitrogen dioxide (NO₂), carbon monoxide (CO), and polycyclic aromatic hydrocarbons (PAHs). Exposure to these pollutants is strongly associated with the development and exacerbation of respiratory diseases, including asthma, chronic obstructive pulmonary disease (COPD), lung cancer, and idiopathic pulmonary fibrosis (IPF).
View Article and Find Full Text PDFJ Hazard Mater
September 2025
Architectural Engineering Department, Pennsylvania State University, University Park, PA, USA. Electronic address:
Far-UVC systems and air cleaners are effective strategies for controlling airborne pathogen transmission, particularly in densely occupied spaces with insufficient ventilation, such as school classrooms. This study evaluates the disinfection performance and ozone (O) formation of different far-UVC systems and air cleaners in a standard-sized classroom using computational fluid dynamics (CFD) simulation. Results show that ceiling-mounted far-UVC systems reduce airborne pathogen exposure by up to 30 % more than upper-room and wall-mounted configurations, based on intake fractions and room-average concentrations.
View Article and Find Full Text PDF