A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Real-Time Observation of Protein Aggregation at Liquid-Liquid Interfaces in a Microfluidic Device. | LitMetric

Real-Time Observation of Protein Aggregation at Liquid-Liquid Interfaces in a Microfluidic Device.

Small

ETH Zürich, Department of Chemistry and Applied Biosciences, Institute for Chemical and Bioengineering, Zürich, 8093, Switzerland.

Published: November 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A droplet microfluidic device to capture in real-time protein aggregation at liquid-liquid interfaces is described. In contrast to conventional methods, typically characterized by a lag time between the application of interfacial stress and the measurement of protein aggregation, here protein adsorption, the formation of a viscoelastic protein layer, aggregation, and shedding of protein particles into solution is simultaneously monitored. The device is applied to analyze the stability of antibody formulations over a wide range of concentrations (1-180 mg mL) at the silicone oil (SO)-water interface under controlled mechanical deformation. The adsorption onto oil droplets induces the formation of a viscoelastic protein layer on a subsecond timescale, which progressively restricts the relaxation of the droplets within the chip. Upon mechanical rupture, the protein layer releases particles in solution. The rate of particle formation increases strongly with concentration, similar to the bulk viscosity. Concentrations above 120 mg mL lead to aggregation in seconds and drastically decrease the mechanical perturbations required to shed protein particles in solution. These results are important for the development of formulations at high-protein concentrations (>100 mg mL) and indicate that particular attention should be given to interface-induced particle formation in this concentration range. In this context, low-volume microfluidic platforms allow the assessment of protein physical instabilities early in development and represent attractive tools to optimize antibody stability and formulation design consuming limited amounts of material.

Download full-text PDF

Source
http://dx.doi.org/10.1002/smll.202401085DOI Listing

Publication Analysis

Top Keywords

protein aggregation
12
protein layer
12
particles solution
12
protein
10
aggregation liquid-liquid
8
liquid-liquid interfaces
8
microfluidic device
8
formation viscoelastic
8
viscoelastic protein
8
protein particles
8

Similar Publications