Article Abstract

Background And Objective: Imaging methodologies such as, computed tomography (CT) aid in three-dimensional (3D) reconstruction of patient-specific aneurysms. The radiological data is useful in understanding their location, shape, size, and disease progression. However, there are serious impediments in discerning the blood vessel wall thickness due to limitations in the current imaging modalities. This further restricts the ability to perform high-fidelity fluid structure interaction (FSI) studies for an accurate assessment of rupture risk. FSI studies would require the arterial wall mesh to be generated to determine realistic maximum allowable wall stresses by performing coupled calculations for the hemodynamic forces with the arterial walls.

Methods: In the present study, a novel methodology is developed to geometrically model variable vessel wall thickness for the lumen isosurface extracted from CT scan slices of patient-specific aneurysms based on clinical and histopathological inputs. FSI simulations are carried out with the reconstructed models to assess the importance of near realistic wall thickness model on rupture risk predictions.

Results: During surgery, clinicians often observe translucent vessel walls, indicating the presence of thin regions. The need to generate variable vessel wall thickness model, that embodies the wall thickness gradation, is closer to such clinical observations. Hence, corresponding FSI simulations performed can improve clinical outcomes. Considerable differences in the magnitude of instantaneous wall shear stresses and von Mises stresses in the walls of the aneurysm was observed between a uniform wall thickness and a variable wall thickness model.

Conclusion: In the present study, a variable vessel wall thickness generation algorithm is implemented. It was shown that, a realistic wall thickness modeling is necessary for an accurate prediction of the shear stresses on the wall as well as von Mises stresses in the wall. FSI simulations are performed to demonstrate the utility of variable wall thickness modeling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medengphy.2024.104211DOI Listing

Publication Analysis

Top Keywords

wall thickness
44
vessel wall
20
wall
17
fsi studies
12
variable vessel
12
fsi simulations
12
thickness
11
arterial wall
8
patient-specific aneurysms
8
rupture risk
8

Similar Publications

Importance: Transthyretin cardiac amyloidosis (ATTR-CA) is an underdiagnosed but treatable cause of heart failure (HF) in older individuals that occurs in the context of normal wild-type (ATTRwt-CA) or an abnormal inherited (ATTRv-CA) TTR gene variant. While the most common inherited TTR variant, V142I, occurs in 3% to 4% of self-identified Black Americans and is associated with excess morbidity and mortality, the prevalence of ATTR-CA in this at-risk population is unknown.

Objective: To define the prevalence of ATTR-CA and proportions attributable to ATTRwt-CA or ATTRv-CA among older Black and Caribbean Hispanic individuals with HF.

View Article and Find Full Text PDF

Objective This research investigated the application of real-time, three-dimensional speckle tracking imaging (RT-3D-STI) to evaluate left atrial (LA) function in individuals suffering from hypertensive heart disease (HHD) and heart failure with preserved ejection fraction (HFpEF).Material and methods This retrospective study included 100 patients with HHD and HFpEF hospitalized from August 2023to June 2024 (HFpEF group). 100 healthy individuals undergoing physical examinations comprised the control group.

View Article and Find Full Text PDF

Background And Aim: Echocardiographic assessment in equines is typically performed on standing animals; however, no studies have evaluated left ventricular function in anesthetized mules using high-dose xylazine. Given the unique pharmacokinetics in mules and their higher anesthetic requirements, this study aimed to assess the effects of acepromazine-xylazine-diazepam-ketamine anesthesia, using the upper limit xylazine dose (1.6 mg/kg), on the left ventricular size and function in mules.

View Article and Find Full Text PDF

The study of the self-assembly of surfactants in aqueous solutions, though a traditional field, remains fascinating and full of novelty. In this article, the anionic perfluorodecanoic acid surfactant (PFA) is separately complexed with three hydroxyalkylamines (monoethanolamine (MEA), diethylamine (DEA), and triethanolamine (TEA)) in aqueous solutions. The transformation of aggregate morphologies from spherical unilamellar to nanotubes and then to spherical bilamellar is observed at room temperature, which is confirmed by cryo-transmission electron microscopy (cryo-TEM).

View Article and Find Full Text PDF

Objective: To develop and validate a prognostic nomogram for predicting the risk of proximal ureteral impacted calculi, supporting personalized clinical management.

Methods: This retrospective, multicenter study employed a continuous cohort of 391 patients with proximal ureteral stones treated between January 2021 and April 2024. Data from Longyan People's Hospital (affiliated with Xiamen Medical College) comprised the training set, while independent external validation was performed using data from The Fifth Affiliated Hospital of Fujian University of Traditional Chinese Medicine.

View Article and Find Full Text PDF