Dual-Responsive Reconfigurable Miniature Fiberbots: A Study for Vascular Embolization.

Research (Wash D C)

Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR, China.

Published: July 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Navigating the intricate and narrow vascular pathways of the body remains a formidable challenge in vascular embolization, often limiting the maneuverability and steerability of traditional catheters. This study, by T.T. Xu and co-workers, introduces dual-responsive reconfigurable miniature fiberbots, which are capable of catheter-assisted deployment, navigation, and embolization in vascular systems. Through meticulous design and magnetic control, this work successfully validates a multistage vascular embolization approach in the renal artery of rabbits in vivo. The experiments not only overcome the existing limitations of conventional catheterization techniques but also open new avenues for minimally invasive treatments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11328367PMC
http://dx.doi.org/10.34133/research.0404DOI Listing

Publication Analysis

Top Keywords

vascular embolization
12
dual-responsive reconfigurable
8
reconfigurable miniature
8
miniature fiberbots
8
vascular
5
fiberbots study
4
study vascular
4
embolization
4
embolization navigating
4
navigating intricate
4

Similar Publications

Background: Perforation of artery causing bleeding is a rare but serious complication of percutaneous coronary intervention (PCI), with potentially life-threatening consequences. Prompt recognition and management are crucial, particularly in high-risk patients or complex procedures. Coils are essential tools for sealing perforated or ruptured vessels, preventing further haemorrhage and stabilising the patient.

View Article and Find Full Text PDF

Congenital intrahepatic portosystemic shunts are uncommon vascular anomalies that can lead to hyperammonemia and liver dysfunction. We report a 48-year-old woman with a large intrahepatic shunt presenting with elevated blood ammonia and progressive hepatic atrophy. She underwent percutaneous coil-in-plug embolization using an Amplatzer Vascular Plug II filled with coils.

View Article and Find Full Text PDF

We present a rare anatomical variation of the deep femoral vein (DFV) originating from the popliteal vein (PV) with an associated aneurysm. The DFV arose from the PV at the adductor hiatus, exhibited an aneurysm, and coursed upward through the fourth osseo-aponeurotic opening of the adductor magnus muscle to enter the anterior thigh compartment before draining into the femoral vein. This unique variation likely resulted from developmental deviations during intrauterine life.

View Article and Find Full Text PDF

[A case report of tracheobronchial Dieulafoy's disease].

Zhonghua Jie He He Hu Xi Za Zhi

September 2025

Department of Respiratory and Critical Care Medicine, the First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China.

Tracheobronchial Dieulafoy's disease (TBDD) is a rare bronchial artery vascular malformation, characterized clinically by sudden, recurrent, and life-threatening massive hemoptysis. This article reports the case of a 9-year-old female patient who presented with massive hemoptysis lasting two weeks. Following ineffective treatment at a local hospital, she was transferred to our institution.

View Article and Find Full Text PDF

Introduction: Benchtop and animal models have traditionally been used to study the propagation of Onyx Liquid Embolic Systems (Onyx) used in the treatment of brain arteriovenous malformations (AVM). However, such models are costly, do not provide sufficient detail to elucidate how variations in Onyx viscosity alter flow dynamics, and rely on some trial-and-error, resulting in elongated timelines for product development.

Objectives: The goal of this study was to leverage Computational Fluid Dynamics (CFD) simulations to predict the behavior of different Onyx formulations.

View Article and Find Full Text PDF